Intrapulmonary gas mixing and pulmonary gas exchange in artificially ventilated dogs
- PMID: 8272372
- DOI: 10.1007/BF00374498
Intrapulmonary gas mixing and pulmonary gas exchange in artificially ventilated dogs
Abstract
To investigate the effect of incomplete gas mixing between tidal air and residual gas on pulmonary gas exchange, anaesthetized dogs were ventilated artificially with breathing patterns with different durations of the post-inspiratory apnoea (ta = 0, 0.5, 1.0 and 2.0 s), where tidal volume, breathing frequency, inspiratory and expiratory flow patterns were kept constant. We determined the alveolar ventilations (VA) of He and SF6 from the product of end-expiratory lung volume (VL,E') and specific ventilation (VA/VL,E'). VL,E' was determined by the dilution technique and the specific ventilations of the two gases were obtained from their multiple-breath washout. Further, tracer amounts of acetone, ether and enflurane were infused continuously into a peripheral vein and a bolus of a gas mixture of krypton, Freon12 and SF6 was introduced into the peritoneal cavity. We determined the Excretion (E) and Retention (R) of these six gases according to the multiple-inert-gas-elimination technique (MIGET). VA increased with increasing ta, where VA,He was about 14% larger than VA,SF6. For both gases, however, the increase in VA relative to control (VA for ta = 0) was virtually the same: 9, 11 and 19% (mean values) for ta = 0.5, 1.0 and 2.0 s respectively. For all dogs the E/R curve shifted to larger E values with increasing ta. E for the most soluble tracer gas (acetone) increased by 11, 21 and 25% for ta = 0.5, 1.0 and 2.0 s respectively. VA, determined with MIGET from the ventilation/perfusion distribution, increased by almost the same percentages.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Intrapulmonary gas mixing and dead space in artificially ventilated dogs.Pflugers Arch. 1995 Sep;430(5):862-70. doi: 10.1007/BF00386187. Pflugers Arch. 1995. PMID: 7478944
-
Alveolar slope and dead space of He and SF6 in dogs: comparison of airway and venous loading.J Appl Physiol (1985). 1990 Sep;69(3):937-44. doi: 10.1152/jappl.1990.69.3.937. J Appl Physiol (1985). 1990. PMID: 2246182
-
Cardiogenic oscillations in He and SF6 expirograms during airway and venous loading.J Appl Physiol (1985). 1990 Sep;69(3):945-55. doi: 10.1152/jappl.1990.69.3.945. J Appl Physiol (1985). 1990. PMID: 2123180
-
[Gas exchange in acute respiratory distress syndrome].Medicina (B Aires). 2003;63(2):157-64. Medicina (B Aires). 2003. PMID: 12793087 Review. Spanish.
-
Mechanisms of gas transport during ventilation by high-frequency oscillation.J Appl Physiol Respir Environ Exerc Physiol. 1984 Mar;56(3):553-63. doi: 10.1152/jappl.1984.56.3.553. J Appl Physiol Respir Environ Exerc Physiol. 1984. PMID: 6368498 Review.
Cited by
-
Intrapulmonary gas mixing and dead space in artificially ventilated dogs.Pflugers Arch. 1995 Sep;430(5):862-70. doi: 10.1007/BF00386187. Pflugers Arch. 1995. PMID: 7478944