T2-weighted MR imaging of the abdomen: fast spin-echo vs conventional spin-echo sequences
- PMID: 8273691
- DOI: 10.2214/ajr.162.1.8273691
T2-weighted MR imaging of the abdomen: fast spin-echo vs conventional spin-echo sequences
Abstract
Objective: The purpose of this study was to compare one optimized T2-weighted fast spin-echo sequence with one T2-weighted conventional spin-echo sequence to determine the impact of fast spin echo on image quality and diagnostic efficacy for evaluation of the abdomen.
Subjects and methods: A total of 32 patients with 43 lesions involving various abdominal organs were examined. T2-weighted fast spin-echo (4000/119/4, echo train length = 16, matrix = 256 x 256) and T2-weighted conventional spin-echo (3400-3800/80/2, matrix = 128 x 256) images were compared qualitatively and quantitatively to determine whether the two types of images differed with respect to tissue contrast, conspicuousness of lesions, image quality, and artifacts.
Results: The signal intensity of all abdominal structures (except gallbladder and fat) was significantly lower on fast spin-echo images than on conventional spin-echo images. Qualitative liver-to-spleen contrast was significantly reduced on fast spin-echo images, whereas quantitative liver-to-spleen contrast was not significantly different. Blurring of anatomic structures, vascular pulsation, and chemical-shift misregistration artifacts were significantly reduced on fast spin-echo images. The qualitative conspicuousness and contrast-to-noise ratio for all lesions evaluated together were not significantly different (p = .5 and p = .069, respectively) on fast spin-echo vs conventional spin-echo images. However, qualitative conspicuousness and contrast-to-noise ratio of solid lesions were significantly reduced on fast spin-echo images (p = .022 and p = .01, respectively). The contrast-to-noise ratio of cystic lesions was significantly better (p = .002) on fast spin-echo images than on conventional spin-echo images.
Conclusion: Although the fast spin-echo protocol used in this study provides better image quality and contrast-to-noise ratio for cystic abdominal lesions than does conventional spin echo, the qualitative conspicuousness and contrast-to-noise ratio of solid abdominal lesions are decreased. Fast spin echo provides high-quality images with fewer artifacts in significantly less time than is possible with conventional spin-echo images. Further evaluation is necessary to determine the optimal protocol for T2-weighted fast spin-echo MR imaging of the abdomen.
Similar articles
-
T2-weighted MR imaging of the upper part of the abdomen: should fat suppression be used routinely?AJR Am J Roentgenol. 1994 May;162(5):1095-100. doi: 10.2214/ajr.162.5.8165989. AJR Am J Roentgenol. 1994. PMID: 8165989
-
Fast multiplanar spoiled gradient-recalled imaging of the liver: pulse sequence optimization and comparison with spin-echo MR imaging.AJR Am J Roentgenol. 1993 Mar;160(3):501-9. doi: 10.2214/ajr.160.3.8381572. AJR Am J Roentgenol. 1993. PMID: 8381572
-
MR imaging of the brain: comparison of gradient-echo and spin-echo pulse sequences.AJR Am J Roentgenol. 1995 Oct;165(4):959-62. doi: 10.2214/ajr.165.4.7677001. AJR Am J Roentgenol. 1995. PMID: 7677001
-
Utility of the FIESTA pulse sequence in body oncologic imaging: review.AJR Am J Roentgenol. 2009 Jun;192(6 Suppl):S83-93 (Quiz S94-7). doi: 10.2214/AJR.07.7062. AJR Am J Roentgenol. 2009. PMID: 19458102 Review.
-
Abdominal applications of 3.0-T MR imaging: comparative review versus a 1.5-T system.Radiographics. 2008 Jul-Aug;28(4):e30. doi: 10.1148/rg.e30. Epub 2008 Apr 21. Radiographics. 2008. PMID: 18426969 Review.
Cited by
-
Receiver operating characteristic analysis of diffusion-weighted magnetic resonance imaging in differentiating hepatic hemangioma from other hypervascular liver lesions.J Comput Assist Tomogr. 2008 Sep-Oct;32(5):750-6. doi: 10.1097/RCT.0b013e31816a6823. J Comput Assist Tomogr. 2008. PMID: 18830105 Free PMC article.
-
MR imaging of focal liver lesions: comparison between turbo spin-echo and conventional spin-echo pulse sequences.MAGMA. 1995 Sep-Dec;3(3-4):143-50. doi: 10.1007/BF01771699. MAGMA. 1995. PMID: 8749732 Clinical Trial.
-
The role of radiologic imaging and biopsy in renal tumor ablation.World J Urol. 2010 Oct;28(5):551-7. doi: 10.1007/s00345-010-0549-z. Epub 2010 Apr 24. World J Urol. 2010. PMID: 20419303 Review.
-
Liver MR imaging: comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery.Abdom Imaging. 1996 Sep-Oct;21(5):433-9. doi: 10.1007/s002619900098. Abdom Imaging. 1996. PMID: 8832865
-
The detection and discrimination of malignant and benign focal hepatic lesions: T2 weighted vs diffusion-weighted MRI.Br J Radiol. 2011 Apr;84(1000):319-26. doi: 10.1259/bjr/50130643. Epub 2010 Oct 19. Br J Radiol. 2011. PMID: 20959371 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical