The Australian Incident Monitoring Study. The stethoscope: applications and limitations--an analysis of 2000 incident reports
- PMID: 8273878
- DOI: 10.1177/0310057X9302100514
The Australian Incident Monitoring Study. The stethoscope: applications and limitations--an analysis of 2000 incident reports
Abstract
The first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS) were analysed with respect to the role of the oesophageal or precordial stethoscope as a continuous monitor. There were 1099 of the 1256 incidents during general anaesthesia in which one might have been used in this way, but use was reported in only 65 cases (5%), predominantly during paediatric cases. In only one report, a cardiac arrest, was the stethoscope the first to detect the incident. In a theoretical analysis it was considered that the stethoscope, used on its own for continuous monitoring, could have detected 54% of the 1256 incidents (almost 25% before any potential for organ damage), had they been allowed to evolve. However, AIMS data suggest that the actual yield using a stethoscope as a continuous monitor may be much lower than this, and that even the use of a "mobile" stethoscope can not be relied upon to detect oesophageal or endobronchial intubation. These reports confirm that there is limited use of the stethoscope for continuous monitoring in current anaesthetic practice in Australia; it has been superseded by the sophisticated electronic monitors now available. However, in areas with limited resources continuous auscultation with a stethoscope remains a basic requirement.
Similar articles
-
The Australian Incident Monitoring Study. Which monitor? An analysis of 2000 incident reports.Anaesth Intensive Care. 1993 Oct;21(5):529-42. doi: 10.1177/0310057X9302100508. Anaesth Intensive Care. 1993. PMID: 8273872
-
The Australian Incident Monitoring Study. The oxygen analyser: applications and limitations--an analysis of 200 incident reports.Anaesth Intensive Care. 1993 Oct;21(5):570-4. doi: 10.1177/0310057X9302100513. Anaesth Intensive Care. 1993. PMID: 8273877
-
The Australian Incident Monitoring Study. The pulse oximeter: applications and limitations--an analysis of 2000 incident reports.Anaesth Intensive Care. 1993 Oct;21(5):543-50. doi: 10.1177/0310057X9302100509. Anaesth Intensive Care. 1993. PMID: 8273873
-
The pretracheal stethoscope useful, but not a necessity.Paediatr Anaesth. 2016 Mar;26(3):256-8. doi: 10.1111/pan.12842. Paediatr Anaesth. 2016. PMID: 26814036 Review. No abstract available.
-
Critical incident monitoring in anaesthesia.Curr Opin Anaesthesiol. 2008 Apr;21(2):183-6. doi: 10.1097/ACO.0b013e3282f33592. Curr Opin Anaesthesiol. 2008. PMID: 18443485 Review.
Cited by
-
Beat-to-Beat Tracking of Pulse Pressure and Its Respiratory Variation Using Heart Sound Signal in Patients Undergoing Liver Transplantation.J Clin Med. 2019 Apr 30;8(5):593. doi: 10.3390/jcm8050593. J Clin Med. 2019. PMID: 31052236 Free PMC article.
-
An endotracheal intubation confirmation system based on carina image detection: a proof of concept.Med Biol Eng Comput. 2011 Jan;49(1):75-83. doi: 10.1007/s11517-010-0680-4. Epub 2010 Sep 29. Med Biol Eng Comput. 2011. PMID: 20878551
-
Electrically amplified precordial stethoscope.J Clin Monit. 1994 Nov;10(6):410-2. doi: 10.1007/BF01618424. J Clin Monit. 1994. PMID: 7836978 No abstract available.
-
Novel automatic endotracheal position confirmation system: mannequin model algorithm evaluation.J Clin Monit Comput. 2010 Oct;24(5):335-40. doi: 10.1007/s10877-010-9253-1. Epub 2010 Aug 13. J Clin Monit Comput. 2010. PMID: 20706778
-
Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.BMJ. 2010 Nov 9;341:c5943. doi: 10.1136/bmj.c5943. BMJ. 2010. PMID: 21062875 Free PMC article. Clinical Trial.