Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1993 Oct;21(5):602-7.
doi: 10.1177/0310057X9302100518.

The Australian Incident Monitoring Study. Difficult intubation: an analysis of 2000 incident reports

Affiliations

The Australian Incident Monitoring Study. Difficult intubation: an analysis of 2000 incident reports

J A Williamson et al. Anaesth Intensive Care. 1993 Oct.

Abstract

The first 2000 incidents reported to the Australian Incident Monitoring Study were analysed with respect to the incidence and circumstances of problems with endotracheal intubation; 85 (4%) indicated difficulties with intubation. One third of these were emergency cases, one third involved an initially unassisted trainee and one fifth were outside normal working hours. Failure to predict a difficult intubation was reported in one third of the cases, with another quarter presenting serious difficulty despite preoperative prediction. Difficulties with ventilation were experienced in 1 in 7 of the 85 reports; there was one cardiac arrest, but no death. Endotracheal intubation was not achieved in one fifth of the cases. The commonest complications reported amongst the 85 incidents were oesophageal intubation (18 cases), arterial desaturation (15 cases), and reflux of gastric contents (7 cases). Emergency trans-tracheal airways were required in 5 cases. Obesity, limited neck mobility and mouth opening, and inadequate assistance together accounted for two thirds of all the contributing factors. The most successful intubation aid in this series was a gum elastic bougie. A capnograph contributed to management in 28% and a pulse oximeter in 12% of the cases in which they were used. The most serious desaturations were associated with accidental oesophageal intubation. These data suggest a lack of reliable preoperative assessment techniques and skills for the prediction of difficult intubations. They also suggest the need for a greater emphasis on ensuring that the necessary equipment is available, and on teaching and learning drills for difficult intubation and any associated difficulty with ventilation.

PubMed Disclaimer

Comment in

  • AIMS and difficult intubation.
    Mackie D. Mackie D. Anaesth Intensive Care. 1994 Apr;22(2):234-5. Anaesth Intensive Care. 1994. PMID: 8210037 No abstract available.

Similar articles

Cited by

MeSH terms

LinkOut - more resources