Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1994 Jan;23(1):92-8.
doi: 10.1016/0735-1097(94)90506-1.

Positron emission tomography detects evidence of viability in rest technetium-99m sestamibi defects

Affiliations
Free article
Comparative Study

Positron emission tomography detects evidence of viability in rest technetium-99m sestamibi defects

S G Sawada et al. J Am Coll Cardiol. 1994 Jan.
Free article

Abstract

Objectives: The purpose of this study was to determine the relative value of single-photon emission computed tomographic (SPECT) imaging at rest using technetium-99m methoxyisobutyl isonitrile (technetium-99m sestamibi) with positron emission tomography for detection of viable myocardium.

Background: Recent studies comparing positron emission tomography and thallium-201 reinjection with rest technetium-99m sestamibi imaging have suggested that the latter technique underestimates myocardial viability.

Methods: Twenty patients with a previous myocardial infarction underwent rest technetium-99m sestamibi imaging and positron emission tomography using fluorine (F)-18 deoxyglucose and nitrogen (N)-13 ammonia. In each patient, circumferential profile analysis was used to determine technetium-99m sestamibi, F-18 deoxyglucose and N-13 ammonia activity (expressed as percent of peak activity) in nine cardiac segments and in the perfusion defect defined by the area having technetium-99m sestamibi activity < 60%. Technetium-99m sestamibi defects were graded as moderate (50% to 59% of peak activity) and severe (< 50% of peak activity). Estimates of perfusion defect size were compared between technetium-99m sestamibi and N-13 ammonia.

Results: Sixteen (53%) of 30 segments with moderate defects and 16 (47%) of 34 segments with severe defects had > or = 60% F-18 deoxyglucose activity considered indicative of viability. Fluorine-18 deoxyglucose evidence of viability was still present in 50% of segments with technetium-99m sestamibi activity < 40%. There was no significant difference in the mean (+/- SD) technetium-99m sestamibi activity in segments with viable (40 +/- 7%) and nonviable segments (49 +/- 7%, p = 0.84). Of the 18 patients who had adequate F-18 deoxyglucose studies, the area of the technetium-99m sestamibi defect was viable in 5 (28%). In 16 patients (80%), perfusion defect size determined by technetium-99m sestamibi exceeded that measured by N-13 ammonia. The difference in defect size between technetium-99m sestamibi and N-13 ammonia was significantly greater in patients with viable (21 +/- 9%) versus nonviable segments (7 +/- 9%, p = 0.007).

Conclusions: Moderate and severe rest technetium-99m sestamibi defects frequently have metabolic evidence of viability. Technetium-99m sestamibi SPECT yields larger perfusion defects than does N-13 ammonia positron emission tomography when the same threshold values are used.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources