A surgical technique for bilateral cochleotomy in the Long-Evans rat
- PMID: 8292571
- DOI: 10.3109/08941939309141630
A surgical technique for bilateral cochleotomy in the Long-Evans rat
Abstract
A bilateral cochleotomized surgical rat model, needed for a study involving microwave effects, was developed, standardized, and assessed for reproducibility. After a review of the literature concerning attempts and approaches with various species, a technique involving an approach through the external auditory canal was chosen and modified. Using a stereomicroscope, a cutaneous incision in the intertragic notch was made and extended medially along the ventral aspect of the external auditory canal to the depth of the external auditory meatus. The tympanic membrane was ruptured and the malleus removed with splinter forceps, allowing visualization of the cochlea. The lateral wall of the cochlea was penetrated with a 0.024-in. wire gauge drill bit and endolymph was suctioned from the cochlea. A 5-mm piece of 3-O silk suture, inserted into the cochlear opening, maintained patency. Appraisal of the reliability and standardization of the procedure was performed utilizing startleometry. Histology assessed completeness of the procedure and any evidence of cochlear infection.
Similar articles
-
Exploratory cochleotomy. Assessment of auditory nerve excitability and anatomical conditions in cochlear implant candidates.ORL J Otorhinolaryngol Relat Spec. 1992;54(6):295-8. doi: 10.1159/000276318. ORL J Otorhinolaryngol Relat Spec. 1992. PMID: 1475098
-
Improved auditory performance of cochlear implant patients using the middle fossa approach.Audiology. 1999 Jul-Aug;38(4):225-34. doi: 10.3109/00206099909073026. Audiology. 1999. PMID: 10431908
-
Ineraid cochlear implant in the ossified cochlea: surgical techniques and results.Am J Otol. 1994 Nov;15(6):748-51. Am J Otol. 1994. PMID: 8572086 Clinical Trial.
-
[Cochlear implantation--the Viennese surgical technique].Wien Klin Wochenschr. 2000 Jun 2;112(11):473-6. Wien Klin Wochenschr. 2000. PMID: 10890123 Review. German.
-
Cochlear implant electrode insertion: in defence of cochleostomy and factors against the round window membrane approach.Cochlear Implants Int. 2011 Aug;12 Suppl 2:S36-9. doi: 10.1179/146701011X13074645127478. Cochlear Implants Int. 2011. PMID: 21917217 Review.
Cited by
-
Cochlear implantation in rats: a new surgical approach.Hear Res. 2005 Jul;205(1-2):115-22. doi: 10.1016/j.heares.2005.03.010. Hear Res. 2005. PMID: 15953521 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical