Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1993;19(8):443-9.
doi: 10.1007/BF01711084.

Long-term inhalation with evaluated low doses of nitric oxide for selective improvement of oxygenation in patients with adult respiratory distress syndrome

Affiliations
Clinical Trial

Long-term inhalation with evaluated low doses of nitric oxide for selective improvement of oxygenation in patients with adult respiratory distress syndrome

H Gerlach et al. Intensive Care Med. 1993.

Abstract

Objective: To evaluate the lowest dose of inhaled nitric oxide (NO) in patients with adult respiratory distress syndrome (ARDS), which is able to improve arterial oxygenation more than 30% compared to baseline data.

Design: Prospective, clinical study.

Setting: Anesthesiological ICU in a university hospital.

Patients: 3 consecutive patients with severe ARDS according to clinical and radiological signs.

Interventions: Pressure-controlled ventilation with positive end-expiratory pressure of 8-12 cm H2O. Inhalation of NO was performed with a blender system and a Servo 300 ventilator. The lowest effective NO dose was defined by titrating the inspiratory NO dose until reaching a 30% improvement of PaO2/FiO2. This dose was used for the following continuous long-term NO inhalation; controls of efficacy by investigation of hemodynamics and blood gas exchange were performed initially and 2 times per patient after intervals of 3-5 days.

Measurements and results: Initial NO concentrations were found to be effective at 60, 100, and 230 parts per billion (ppb). In all measurements, arterial oxygenation was found to be elevated by NO inhalation with the initially evaluated dose compared to baseline data; in parallel, the venous admixture (Qva/Qt) was reduced. The O2 delivery increased, although O2 consumption and hemodynamics did not change. In 1 patient, interruption of NO inhalation caused remarkable increase of pulmonary resistance.

Conclusions: The improvement of oxygenation by NO inhalation in ARDS does not require reduction of pulmonary resistance and can be performed using low doses in the ppb range, which has to be considered as probably non-toxic.

PubMed Disclaimer

Comment in

References

    1. Anesthesiology. 1988 Jan;68(1):152-7 - PubMed
    1. Anesthesiology. 1989 Apr;70(4):601-6 - PubMed
    1. Am Rev Respir Dis. 1985 Jul;132(1):109-14 - PubMed
    1. Circ Res. 1975 Sep;37(3):271-84 - PubMed
    1. Nature. 1988 Jun 16;333(6174):664-6 - PubMed

Publication types

LinkOut - more resources