. 1994 Jan;67(793):46-53.
doi: 10.1259/0007-1285-67-793-46.

A new method of quantification of the pulmonary regional distribution of aerosols using combined CT and SPECT and its application to nedocromil sodium administered by metered dose inhaler

Affiliations

A new method of quantification of the pulmonary regional distribution of aerosols using combined CT and SPECT and its application to nedocromil sodium administered by metered dose inhaler

S Perring et al. Br J Radiol. 1994 Jan.

Abstract

Aerosols of nedocromil sodium labelled with 99Tcm were delivered on 20 separate occasions to healthy male volunteers. Planar and single photon emission computerized tomography (SPECT) gamma scintigraphy were immediately performed to assess the pulmonary regional distribution of delivered aerosol. On a separate occasion volunteers were imaged using X-ray computed tomography (CT). Alignment of SPECT and CT images was performed using marked anatomical features and the anterior and lateral skin outlines. CT images provided data for attenuation correction and were used to define the anatomical lung volume. Central to peripheral (CP) ratios of deposited activity were calculated from volumes of interest in coronal and transverse sections of the right lung. These were compared with CP ratios obtained from planar images obtained immediately following aerosol inhalation. Volumetric CP ratio correlated significantly with immediate planar CP ratio (p < 0.001). Analysis of deposition in the whole right lung was performed by separating the SPECT lung data into a series of thin concentric shells centred on the entry of the right main bronchus. Measures were defined for describing the variation of deposition density and cumulative total deposition with distance from the lung centre. These showed significant correlation with planar CP ratio (p < 0.001). SPECT analysis using CT is consistent with planar measures of aerosol deposition but offers a more complete quantification of aerosol penetration and absolute deposited activity within the whole lung. It is a valuable new tool for aerosol analysis.