Causes of dislocation of total hip arthroplasty. CT study of component alignment
- PMID: 8300680
Causes of dislocation of total hip arthroplasty. CT study of component alignment
Abstract
We reviewed radiographs and CT scans of 38 total hip arthroplasties which had dislocated (36 posteriorly; 2 anteriorly) and compared the alignment of the prosthetic components with those of 14 uncomplicated arthroplasties. No difference was found between the alignment of the prosthetic components in the two groups. In the seven patients who had reoperations, the cause of dislocation diagnosed by CT was confirmed in only two cases (one retroversion of the cup and one protruding osteophyte). Muscular imbalance rather than malposition of the components was the major factor determining dislocation. CT allows accurate measurement of cup and neck anteversion but contributes little to preoperative planning.
Similar articles
-
Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty.Clin Orthop Relat Res. 1992 Mar;(276):206-9. Clin Orthop Relat Res. 1992. PMID: 1537154
-
The effect of acetabular and femoral component version on dislocation in primary total hip arthroplasty.Int Orthop. 2016 Apr;40(4):697-702. doi: 10.1007/s00264-015-2924-2. Epub 2015 Jul 23. Int Orthop. 2016. PMID: 26202021
-
Classification and treatment of dislocations of total hip arthroplasty.Clin Orthop Relat Res. 1983 Mar;(173):151-8. Clin Orthop Relat Res. 1983. PMID: 6825326
-
Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component.J Bone Joint Surg Br. 2005 Jun;87(6):762-9. doi: 10.1302/0301-620X.87B6.14745. J Bone Joint Surg Br. 2005. PMID: 15911655 Review.
-
Managing chronic dislocated total hip arthroplasty.Semin Arthroplasty. 1993 Jan;4(1):16-24. Semin Arthroplasty. 1993. PMID: 10148093 Review.
Cited by
-
Can we trust combined anteversion and Lewinnek safe zone to avoid hip prosthesis dislocation?J Clin Orthop Trauma. 2021 Aug 8;21:101562. doi: 10.1016/j.jcot.2021.101562. eCollection 2021 Oct. J Clin Orthop Trauma. 2021. PMID: 34434695 Free PMC article.
-
Evaluation of bony impingement in regard to internal rotation limit after total hip arthroplasty using rotation matrix.J Rural Med. 2012;7(1):20-4. doi: 10.2185/jrm.7.20. Epub 2012 Jul 7. J Rural Med. 2012. PMID: 25648624 Free PMC article.
-
Current Concepts in Acetabular Positioning in Total Hip Arthroplasty.Indian J Orthop. 2017 Jul-Aug;51(4):386-396. doi: 10.4103/ortho.IJOrtho_144_17. Indian J Orthop. 2017. PMID: 28790467 Free PMC article.
-
Evidence-based computer-navigated total hip arthroplasty: an updated analysis of randomized controlled trials.Eur J Orthop Surg Traumatol. 2014 May;24(4):531-8. doi: 10.1007/s00590-013-1222-1. Epub 2013 Apr 16. Eur J Orthop Surg Traumatol. 2014. PMID: 23589032 Review.
-
Intra- and intersurgeon variability in image-free navigation system for THA.Clin Orthop Relat Res. 2009 Sep;467(9):2305-9. doi: 10.1007/s11999-009-0833-7. Epub 2009 Apr 21. Clin Orthop Relat Res. 2009. PMID: 19381745 Free PMC article.