Long-term results of uncemented alumina acetabular implants
- PMID: 8300682
Long-term results of uncemented alumina acetabular implants
Abstract
We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.
Similar articles
-
Alumina ceramic bearings for hip endoprostheses: the Austrian experiences.Clin Orthop Relat Res. 2000 Oct;(379):85-93. doi: 10.1097/00003086-200010000-00012. Clin Orthop Relat Res. 2000. PMID: 11039796
-
Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing.Orthopedics. 2010 Nov 2;33(11):796. doi: 10.3928/01477447-20100924-11. Orthopedics. 2010. PMID: 21053885
-
[Cementless acetabular fixation with solid alumina sockets. Apropos of 62 total hybrid prostheses with press-fit alumina sockets at 6-year mean follow-up].Rev Chir Orthop Reparatrice Appar Mot. 2000 Sep;86(5):474-81. Rev Chir Orthop Reparatrice Appar Mot. 2000. PMID: 10970971 Clinical Trial. French.
-
The use of dense alumina-alumina ceramic combination in total hip replacement.J Biomed Mater Res. 1988 Dec;22(12):1203-32. doi: 10.1002/jbm.820221210. J Biomed Mater Res. 1988. PMID: 3069846 Review.
-
The response to particulate debris.Orthop Clin North Am. 1993 Oct;24(4):571-81. Orthop Clin North Am. 1993. PMID: 8414422 Review.
Cited by
-
[Pyrocarbon prosthesis for finger interphalangeal joint replacement. Experience after one year].Unfallchirurg. 2005 May;108(5):365-9. doi: 10.1007/s00113-004-0891-y. Unfallchirurg. 2005. PMID: 15909206 Clinical Trial. German.
-
[Results of cementless hip arthroplasty].Radiologe. 2006 Sep;46(9):779-82, 784. doi: 10.1007/s00117-006-1357-8. Radiologe. 2006. PMID: 16552511 German.
-
Mediators of the inflammatory response to joint replacement devices.Nat Rev Rheumatol. 2011 Sep 6;7(10):600-8. doi: 10.1038/nrrheum.2011.128. Nat Rev Rheumatol. 2011. PMID: 21894210 Review.
-
Is wear debris responsible for failure in alumina-on-alumina implants?Acta Orthop. 2009 Apr;80(2):162-7. doi: 10.3109/17453670902876730. Acta Orthop. 2009. PMID: 19404796 Free PMC article.
-
High survivorship with a titanium-encased alumina ceramic bearing for total hip arthroplasty.Clin Orthop Relat Res. 2014 Feb;472(2):611-6. doi: 10.1007/s11999-013-2943-5. Clin Orthop Relat Res. 2014. PMID: 23543419 Free PMC article.