Osteolysis and component loosening secondary to polyethylene (PE) debris are of paramount concern to today's joint replacement surgeon. This retrospective clinical study measures linear wear in 568 implanted total hip prostheses in which three different metals were used as bearing surfaces (307 stainless steel T-28 [Zimmer, Warsaw, IN], 162 cobalt chrome Tr-28 [Zimmer], and 99 nonion implanted titanium Miami Orthopedic Surgical Consultants [Biomet, Warsaw, IN] prostheses) implanted by a single surgeon over an 8-year period. The acetabular component in all cases was nonmetal-backed compression-molded PE, and all components were cemented. Linear wear was measured using the radiographic technique described by Livermore et al. (The effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg 72A:518, 1990) in which change in acetabular component thickness is determined from serial radiographs. A separate evaluation of this technique confirmed accuracy to within 0.18 mm. Radiographs were also evaluated for femoral and acetabular radiolucencies, femoral subsidence, and osteolysis. Patients were matched for sex, age, weight, and length of follow-up period to eliminate these retrospective variables for comparison of wear. The patient-matched groups consisted of 77 patients from each group (43 women, 34 men) with the following demographics: age, 66 years; weight, 158.9 lbs.; follow-up period, 7.9 years. Results revealed linear wear rates of 0.06 stainless steel, 0.05 cobalt chrome, and 0.08 titanium in the patient-matched groups.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Polyethylene wear in total hip arthroplasty.Clin Orthop Relat Res. 1995 Aug;(317):7-13. Clin Orthop Relat Res. 1995. PMID: 7671498
-
Cemented total hip replacement cable debris and acetabular construct durability.J Bone Joint Surg Am. 2009 Jul;91(7):1664-70. doi: 10.2106/JBJS.G.00428. J Bone Joint Surg Am. 2009. PMID: 19571089 Free PMC article.
-
Comparison of polyethylene wear in machined versus molded polyethylene.Clin Orthop Relat Res. 1995 Aug;(317):37-43. Clin Orthop Relat Res. 1995. PMID: 7671494
-
Particulate metallic debris in cemented total hip arthroplasty.Clin Orthop Relat Res. 1993 Aug;(293):160-73. Clin Orthop Relat Res. 1993. PMID: 8339477 Review.
-
Biological reactions to wear debris in total joint replacement.Proc Inst Mech Eng H. 2000;214(1):21-37. doi: 10.1243/0954411001535219. Proc Inst Mech Eng H. 2000. PMID: 10718048 Review.
Cited by
-
Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia.Eur J Orthop Surg Traumatol. 2019 Apr;29(3):611-618. doi: 10.1007/s00590-018-2351-3. Epub 2018 Nov 28. Eur J Orthop Surg Traumatol. 2019. PMID: 30488136 Free PMC article.
-
[Titanium deposits on the ceramic heads of dislocated total hip replacements].Orthopade. 2004 Oct;33(10):1194-200. doi: 10.1007/s00132-004-0689-1. Orthopade. 2004. PMID: 15278275 German.
-
Acetabular polyethylene wear and acetabular inclination and femoral offset.Clin Orthop Relat Res. 2009 Nov;467(11):2895-900. doi: 10.1007/s11999-009-0845-3. Epub 2009 May 2. Clin Orthop Relat Res. 2009. PMID: 19412648 Free PMC article.
-
A combined XPS-SEM/EDX investigation on explanted UHMW polyethylene acetabular cups: possible role of silicon traces in the wear debris.J Mater Sci Mater Med. 2001 Jan;12(1):23-8. doi: 10.1023/a:1013802716574. J Mater Sci Mater Med. 2001. PMID: 15348373
-
Unexpected high early failure rate of the Nexel total elbow arthroplasty.JSES Int. 2022 May 6;6(4):690-695. doi: 10.1016/j.jseint.2022.04.001. eCollection 2022 Jul. JSES Int. 2022. PMID: 35813147 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources