History and recent developments in pulse oximetry
- PMID: 8332844
History and recent developments in pulse oximetry
Abstract
To honour Siggaard-Andersen's role in the development of accurate blood oximetry, this paper was abstracted from a recent review and survey of over 750 publications of pulse oximetry. Pulse oximetry usage has become nearly universal during anesthesia and related critical care in the developed world during the last decade. More than 35 manufacturers offer pulse oximetry. Costs of some have fallen to less than $1500 per device, with no necessary on-going charges. Pulse oximeters are remarkable: Accuracy is +/- 2% down to 70% SaO2 without any user calibration, no drift, instantaneous readout, and almost no maintenance or safety problems. New developments include better understanding of management of premature infants, beginning use for fetal SaO2 during labor, sophisticated methods of ignoring motion artifacts and room light interference, and awareness of sources of error. Oximetry use has caused anesthesiologists and most critical care physicians to become far more able to avoid severe hypoxia in patients. Malpractice insurance rates for anesthesiologists have dropped in the USA, and other evidence suggests, although failing to prove, that anesthesia and critical care is now safer, probably due to oximetry.
Similar articles
-
Next-generation pulse oximetry. Focusing on Masimo's signal extraction technology.Health Devices. 2000 Oct;29(10):349-70. Health Devices. 2000. PMID: 11094776
-
Recent findings in the use of reflectance oximetry: a critical review.Curr Opin Anaesthesiol. 2005 Dec;18(6):649-54. doi: 10.1097/01.aco.0000191893.21444.56. Curr Opin Anaesthesiol. 2005. PMID: 16534307
-
A historical overview and update on pulse oximetry.Anesthesiol Rev. 1993 Sep-Oct;20(5):173-81. Anesthesiol Rev. 1993. PMID: 10146466 Review.
-
A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns.Am J Obstet Gynecol. 2000 Nov;183(5):1049-58. doi: 10.1067/mob.2000.110632. Am J Obstet Gynecol. 2000. PMID: 11084540 Clinical Trial.
-
New-generation pulse oximetry in the care of critically ill patients.Am J Crit Care. 2005 Jan;14(1):26-37; quiz 38-9. Am J Crit Care. 2005. PMID: 15608106 Review.
Cited by
-
First-in-human pilot study of a spatial frequency domain oxygenation imaging system.J Biomed Opt. 2011 Aug;16(8):086015. doi: 10.1117/1.3614566. J Biomed Opt. 2011. PMID: 21895327 Free PMC article.
-
The Predictive Value of Pulse Oximeters for Pulse Improvement after Angiography in Infants and Children.Iran J Pediatr. 2016 Jul 10;26(5):e5833. doi: 10.5812/ijp.5833. eCollection 2016 Oct. Iran J Pediatr. 2016. PMID: 28203338 Free PMC article.
-
The use (or otherwise) of pulse in general practice.Br J Gen Pract. 2005 Jul;55(516):501-2. Br J Gen Pract. 2005. PMID: 16004733 Free PMC article. No abstract available.
-
A novel pilot study using spatial frequency domain imaging to assess oxygenation of perforator flaps during reconstructive breast surgery.Ann Plast Surg. 2013 Sep;71(3):308-15. doi: 10.1097/SAP.0b013e31828b02fb. Ann Plast Surg. 2013. PMID: 23945533 Free PMC article. Clinical Trial.
-
Ninety years of pulse oximetry: history, current status, and outlook.J Biomed Opt. 2024 Jun;29(Suppl 3):S33307. doi: 10.1117/1.JBO.29.S3.S33307. Epub 2024 Aug 17. J Biomed Opt. 2024. PMID: 39156662 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources