Influence of patient's weight on dual-photon absorptiometry and dual-energy X-ray absorptiometry measurements of bone mineral density
- PMID: 8338975
- DOI: 10.1007/BF01623676
Influence of patient's weight on dual-photon absorptiometry and dual-energy X-ray absorptiometry measurements of bone mineral density
Abstract
Lumbar spine bone mineral density (BMD) was measured by dual-energy X-ray absorptiometry (DXA) (Hologic QDR 1000) and by 153Gd dual-photon absorptiometry (DPA) (Novo Lab 22a) in 120 postmenopausal women. Though a high correlation existed between the two techniques, the ratio between DXA and DPA values was not constant. Using DXA we observed a higher dependence of BMD on weight than in the DPA measurements. To investigate the different behaviour of DXA and DPA machines with weight, we analysed the effects of increasing thickness of soft tissue equivalents on the BMD of the Hologic spine phantom and on the BMD equivalent of an aluminium standard tube. Increasing tissue-equivalent thickness caused the phantom BMD measured by DPA to decrease significantly but had not effect on the DXA measurements. The different behaviour of DPA and DXA equipment with regard to the phantoms could account for the differences observed in the relations between BMD and weight in the patients. Using multiple regression we studied the influence of weight and body mass index on the relation between BMD measured by the two techniques. The introduction of either of these variables into the regression resulted in an improvement of the prediction of the DXA values from the DPA values. However, the residual standard error of the estimate was still higher than the combined precision errors of the two methods, so that no simple relation allows a conversion of BMDDPA into BMDDXA. Our results confirm that BMD is positively correlated with weight in postmenopausal women; the influence of weight on BMD is blunted when the Novo Lab 22a DPA machine is used for measuring bone mineral.
Similar articles
-
An evaluation of dual-energy X-ray absorptiometry and comparison with dual-photon absorptiometry.Osteoporos Int. 1992 May;2(3):146-52. doi: 10.1007/BF01623822. Osteoporos Int. 1992. PMID: 1627902
-
The effect of weight and weight change on the long-term precision of spine and hip DXA measurements.Osteoporos Int. 2011 May;22(5):1503-12. doi: 10.1007/s00198-010-1339-6. Epub 2010 Aug 11. Osteoporos Int. 2011. PMID: 20700581 Clinical Trial.
-
Influence of anthropometric parameters and bone size on bone mineral density using volumetric quantitative computed tomography and dual X-ray absorptiometry at the hip.Acta Radiol. 2006 Jul;47(6):574-80. doi: 10.1080/02841850600690363. Acta Radiol. 2006. PMID: 16875335
-
Bone densitometry.Semin Nucl Med. 2011 May;41(3):220-8. doi: 10.1053/j.semnuclmed.2010.12.002. Semin Nucl Med. 2011. PMID: 21440697 Review.
-
Assessing underlying bone quality in spine surgery patients: a narrative review of dual-energy X-ray absorptiometry (DXA) and alternatives.Spine J. 2021 Feb;21(2):321-331. doi: 10.1016/j.spinee.2020.08.020. Epub 2020 Sep 2. Spine J. 2021. PMID: 32890786 Review.
Cited by
-
Quantitative ultrasound bone measurements: normal values and comparison with bone mineral density by dual X-ray absorptiometry.Calcif Tissue Int. 1995 Jul;57(1):6-10. doi: 10.1007/BF00298988. Calcif Tissue Int. 1995. PMID: 7671166
-
Bone mineral status in paraplegic patients who do or do not perform standing.Osteoporos Int. 1994 May;4(3):138-43. doi: 10.1007/BF01623058. Osteoporos Int. 1994. PMID: 8069052
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous