"Keyhole" method for accelerating imaging of contrast agent uptake
- PMID: 8347963
- DOI: 10.1002/jmri.1880030419
"Keyhole" method for accelerating imaging of contrast agent uptake
Abstract
Magnetic resonance (MR) imaging methods with good spatial and contrast resolution are often too slow to follow the uptake of contrast agents with the desired temporal resolution. Imaging can be accelerated by skipping the acquisition of data normally taken with strong phase-encoding gradients, restricting acquisition to weak-gradient data only. If the usual procedure of substituting zeroes for the missing data is followed, blurring results. Substituting instead reference data taken before or well after contrast agent injection reduces this problem. Volunteer and patient images obtained by using such reference data show that imaging can be usefully accelerated severalfold. Cortical and medullary regions of interest and whole kidney regions were studied, and both gradient- and spin-echo images are shown. The method is believed to be compatible with other acceleration methods such as half-Fourier reconstruction and reading of more than one line of k space per excitation.
Similar articles
-
Dynamic contrast-enhanced MR imaging of the pituitary gland with fast spin-echo technique.J Magn Reson Imaging. 1994 May-Jun;4(3):509-11. doi: 10.1002/jmri.1880040345. J Magn Reson Imaging. 1994. PMID: 8061456
-
Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: comparison of T1-weighted spin-echo and 3D gradient-echo sequences.J Magn Reson Imaging. 1996 May-Jun;6(3):415-24. doi: 10.1002/jmri.1880060302. J Magn Reson Imaging. 1996. PMID: 8724406
-
Dynamic spin-echo imaging: theoretical assessment and implementation.J Magn Reson Imaging. 1994 Nov-Dec;4(6):843-52. doi: 10.1002/jmri.1880040617. J Magn Reson Imaging. 1994. PMID: 7865946
-
Inflammatory joint disease: static and dynamic gadolinium-enhanced MR imaging.J Magn Reson Imaging. 1993 Jan-Feb;3(1):307-10. doi: 10.1002/jmri.1880030142. J Magn Reson Imaging. 1993. PMID: 8428098 Review. No abstract available.
-
Use of MR imaging contrast agents in the brain.J Magn Reson Imaging. 1993 Jan-Feb;3(1):199-218. doi: 10.1002/jmri.1880030133. J Magn Reson Imaging. 1993. PMID: 8428088 Review. No abstract available.
Cited by
-
Magnetic resonance fingerprinting review part 2: Technique and directions.J Magn Reson Imaging. 2020 Apr;51(4):993-1007. doi: 10.1002/jmri.26877. Epub 2019 Jul 25. J Magn Reson Imaging. 2020. PMID: 31347226 Free PMC article. Review.
-
Real-time cardiac MRI with radial acquisition and k-space variant reduced-FOV reconstruction.Magn Reson Imaging. 2018 Nov;53:98-104. doi: 10.1016/j.mri.2018.07.008. Epub 2018 Jul 20. Magn Reson Imaging. 2018. PMID: 30036652 Free PMC article.
-
Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.Magn Reson Med. 2015 Dec;74(6):1574-86. doi: 10.1002/mrm.25546. Epub 2014 Dec 2. Magn Reson Med. 2015. PMID: 25470230 Free PMC article.
-
Time-of-arrival mapping at three-dimensional time-resolved contrast-enhanced MR angiography.Radiology. 2009 Nov;253(2):532-42. doi: 10.1148/radiol.2532082322. Epub 2009 Sep 29. Radiology. 2009. PMID: 19789236 Free PMC article.
-
Reduced field of view imaging using a static second-order gradient for functional MRI applications.Magn Reson Med. 2016 Feb;75(2):817-22. doi: 10.1002/mrm.25650. Epub 2015 Mar 25. Magn Reson Med. 2016. PMID: 25809723 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical