. 1977 Jan-Feb;8(1):92-102.
doi: 10.1161/01.str.8.1.92.

133Xenon inhalation method. Analysis of reproducibility: some of its physiological implications

133Xenon inhalation method. Analysis of reproducibility: some of its physiological implications

U W Blauenstein et al. Stroke. 1977 Jan-Feb.

Abstract

Regional cerebral blood flow (rCBF) was simultaneously measured at seven locations in each hemisphere by the Obrist 133Xenon inhalation method. In each of 35 healthy right-handed subjects two rest measurements were performed on consecutive days. The data analysis comprises the two-compartmentally derived parameters for flow (f1), relative tissue weight (w1), and fractional flow (FF1) respectively of the first compartment, and in addition the initial slope index (ISI). At each detector location the coefficient of variation (C.V.) of the change from first to second measurement was on average 10.4% (ISI), 14.2% (f1), 7.2% (w1), and 2.9% (FF1) respectively. However, when each regional measurement was expressed as a percentage of its hemispheric mean, the C.V. of the intermeasurement change was on average 4.4% (ISI), 7.0% (f1), 7.7% (w1), and 1.9% (FF1) respectively; that of the hemispheric means of ISI, f1, and FF1 was found to be distinctly larger, whereas that of w1 was about equal in size. The interhemispheric coefficient of variation for the change of the hemispheric means from first to second measurement was only 2.3% (ISI), 4.4% (f1), 1.6% (w1), and 1.1% (FF1) respectively. The findings suggest that (1) the variability of rCBF from subject to subject and in consecutive measurements in the same subject is to a substantial degree of physiological origin, and that (2) there are two determinants of rCBF which may operate independently: a determinant of the hemispheric mean level, probably a single determinant for both hemispheres, and a set of determinants for each separate regions superimposed on the hemispheric mean level.

PubMed Disclaimer

Publication types

LinkOut - more resources