Platelet deposition onto polymeric surfaces during shunting
- PMID: 8360203
- DOI: 10.1002/jbm.820270307
Platelet deposition onto polymeric surfaces during shunting
Abstract
In an attempt to develop blood-contacting tubes that can be applied for short-term uses with a reduced heparin concentration or, ideally, without heparinization, we evaluated the blood compatibility of polymeric materials with a rabbit ex vivo shunt model. The shunt tubes employed were made of silicone, plasticized poly(vinyl chloride) (PVC), and segmented poly(ether urethane) (PU). In addition, two kinds of surface-modified tube were used: poly(vinyl alcohol) (PVA)-coated PVC and poly(dimethylacrylamide) (PDMAA)-grafted PU. The ex vivo shunt results correlated well with protein adsorption and platelet adhesion in vitro. The following order for the extent of platelet deposition was given, irrespective of the blood-contacting duration: PDMAA-grafted PU < PVA-coated PVC < PU < silicone, PVC. It is likely that many platelet aggregates detached from the PVA-coated PVC surface. For PDMAA-grafted PU, no trace of detachment of aggregates could be detected on any of the SEM photographs. The number and morphology of blood cells adhered onto the tube surfaces during ex vivo shunting were dependent on the kind of polymer surfaces, the blood exposure time, and the flow rate of blood.
Similar articles
-
Blood compatibility of SPUU-PEO-heparin graft copolymers.J Biomed Mater Res. 1992 Jun;26(6):739-56. doi: 10.1002/jbm.820260605. J Biomed Mater Res. 1992. PMID: 1527098
-
Transient in vivo protein adsorption onto polymeric biomaterials.J Biomed Mater Res. 1979 Jul;13(4):577-91. doi: 10.1002/jbm.820130405. J Biomed Mater Res. 1979. PMID: 88452
-
Evaluation of blood compatibility of PEO grafted and heparin immobilized polyurethanes.J Biomed Mater Res. 1989 Aug;23(A2 Suppl):211-28. J Biomed Mater Res. 1989. PMID: 2674148
-
Negative cilia concept for thromboresistance: synergistic effect of PEO and sulfonate groups grafted onto polyurethanes.J Biomed Mater Res. 1991 May;25(5):561-75. doi: 10.1002/jbm.820250502. J Biomed Mater Res. 1991. PMID: 1869574
-
Copolymers of 2-methacryloyloxyethyl phosphorylcholine (MPC) as biomaterials.Biomed Mater Eng. 2004;14(4):345-54. Biomed Mater Eng. 2004. PMID: 15472384 Review.
Cited by
-
Protein Removal from Hydrogels through Repetitive Surface Degradation.ACS Appl Bio Mater. 2021 Dec 20;4(12):8498-8502. doi: 10.1021/acsabm.1c00993. Epub 2021 Nov 19. ACS Appl Bio Mater. 2021. PMID: 35005931 Free PMC article.
-
Effects of electret coating technology on coronary stent thrombogenicity.Platelets. 2022 Feb 17;33(2):312-319. doi: 10.1080/09537104.2021.1912313. Epub 2021 Apr 15. Platelets. 2022. PMID: 33856288 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous