Measurement of regional cerebral blood flow with positron emission tomography: a comparison of [15O]water to [11C]butanol with distributed-parameter and compartmental models
- PMID: 8360280
- DOI: 10.1038/jcbfm.1993.94
Measurement of regional cerebral blood flow with positron emission tomography: a comparison of [15O]water to [11C]butanol with distributed-parameter and compartmental models
Abstract
To further our understanding of the best way to measure regional CBF with positron emission tomography (PET), we directly compared two candidate tracers ([15O]water and [11C]butanol, administered intravenously) and two popular implementations of the one-compartment (1C) model: the autoradiographic implementation representing a single PET measurement of tissue radioactivity over 1 min and a dynamic implementation representing a sequence of measurements of tissue radioactivity over 200 s. We also examined the feasibility of implementing a more realistic, and thus more complex, distributed-parameter (DP) model by assigning fixed values for all of its parameters other than CBF and tracer volume of distribution (Vd), a requirement imposed by the low temporal resolution and statistical quality of PET data. The studies were performed in three normal adult human subjects during paired rest and visual stimulation. In each subject seven regions of interest (ROIs) were selected, one of which was the primary visual cortex. The corresponding ROI were anatomically equivalent in the three subjects. Regional CBF, Vd, tracer arrival delay, and dispersion were estimated for the dynamic data curves. A total of 252 parameter sets were estimated. With [11C]butanol both implementations of the 1C model provided similar results (r = 0.97). Flows estimated using the 1C models were lower (p < 0.01) with [15O]water than with [11C]butanol. In comparison with the 1C model, the constrained version of the DP used in these studies performed inadequately, overestimating high flow and underestimating low flow with both tracers, possibly as the result of the necessity of assigning fixed values for all of its parameters other than CBF and Vd.
Similar articles
-
Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using [15O]water and [11C]butanol.J Cereb Blood Flow Metab. 1987 Oct;7(5):527-42. doi: 10.1038/jcbfm.1987.102. J Cereb Blood Flow Metab. 1987. PMID: 3498732
-
Measurement of human cerebral blood flow with [15O]butanol and positron emission tomography.J Cereb Blood Flow Metab. 1991 Sep;11(5):707-15. doi: 10.1038/jcbfm.1991.127. J Cereb Blood Flow Metab. 1991. PMID: 1874804
-
Simultaneous correction for tracer arrival delay and dispersion in CBF measurements by the H215O autoradiographic method and dynamic PET.J Nucl Med. 1989 Jun;30(6):1069-78. J Nucl Med. 1989. PMID: 2786948
-
Radioactive oxygen-15 in the study of cerebral blood flow, blood volume, and oxygen metabolism.Semin Nucl Med. 1985 Oct;15(4):377-94. doi: 10.1016/s0001-2998(85)80015-5. Semin Nucl Med. 1985. PMID: 3904006 Review.
-
Kinetic modeling in positron emission tomography.Q J Nucl Med. 2002 Mar;46(1):70-85. Q J Nucl Med. 2002. PMID: 12072847 Review.
Cited by
-
Total-Body Perfusion Imaging with [11C]-Butanol.J Nucl Med. 2023 Nov;64(11):1831-1838. doi: 10.2967/jnumed.123.265659. Epub 2023 Aug 31. J Nucl Med. 2023. PMID: 37652544 Free PMC article.
-
Fully Automated Radiosynthesis of No-Carrier-Added [11C]Butanol Using the GE FASTLab 2 Module.J Labelled Comp Radiopharm. 2025 Jul;68(9-10):e4158. doi: 10.1002/jlcr.4158. J Labelled Comp Radiopharm. 2025. PMID: 40745626 Free PMC article.
-
Noninvasive estimation of the arterial input function in positron emission tomography imaging of cerebral blood flow.J Cereb Blood Flow Metab. 2013 Jan;33(1):115-21. doi: 10.1038/jcbfm.2012.143. Epub 2012 Oct 17. J Cereb Blood Flow Metab. 2013. PMID: 23072748 Free PMC article.
-
Quantitative PET imaging and modeling of molecular blood-brain barrier permeability.medRxiv [Preprint]. 2024 Jul 27:2024.07.26.24311027. doi: 10.1101/2024.07.26.24311027. medRxiv. 2024. Update in: Nat Commun. 2025 Mar 30;16(1):3076. doi: 10.1038/s41467-025-58356-7. PMID: 39108503 Free PMC article. Updated. Preprint.
-
Quantitative hemodynamic PET imaging using image-derived arterial input function and a PET/MR hybrid scanner.J Cereb Blood Flow Metab. 2017 Apr;37(4):1435-1446. doi: 10.1177/0271678X16656200. Epub 2016 Jan 1. J Cereb Blood Flow Metab. 2017. PMID: 27401805 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources