Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1993 Aug;31(8):2114-7.
doi: 10.1128/jcm.31.8.2114-2117.1993.

Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections

Affiliations
Comparative Study

Controlled clinical comparison of two lysis-based blood culture systems, isolator and Septi-Chek Release, for detection of bloodstream infections

B A Kirkley et al. J Clin Microbiol. 1993 Aug.

Abstract

A controlled clinical comparison was made of the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek Release bottle (Roche Diagnostics, Nutley, N.J.). From 6,345 blood culture sets fulfilling minimum criteria for volume of blood cultured, 840 strains were isolated, of which only 691 (82%) were considered to be representative of bloodstream infection according to Centers for Disease Control definitions. Statistically significant differences were found between the systems for the following organisms, which were all detected more frequently in the Isolator system: Staphylococcus aureus (P = 0.0001), Alcaligenes xylosoxidans (P = 0.008), Klebsiella pneumoniae (P = 0.05), Salmonella spp. (P = 0.03), and Candida albicans (P = 0.02). The Septi-Chek Release system required a longer period of time than the Isolator system for detection of the following organisms:S. aureus (P = 0.0001), Enterococcus spp. (P = 0.0001), Enterobacter cloacae (P = 0.03), Escherichia coli (P = 0.0001), Klebsiella oxytoca (P = 0.03), K. pneumoniae (P = 0.02), Pseudomonas aeruginosa (P = 0.002), and C. albicans (P = 0.005). There were 430 episodes of bloodstream infections identified in the study; of these episodes, only those due to S. aureus were detected significantly more frequently (P = 0.0001) by the Isolator system than by the Septi-Chek Release system. However, episodes of bloodstream infections due to S. aureus, Staphylococcus epidermidis, Enterococcus spp., and E. coli were detected significantly faster by the Isolator system.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Infect Control. 1988 Jun;16(3):128-40 - PubMed
    1. Eur J Clin Microbiol Infect Dis. 1991 Aug;10(8):620-4 - PubMed
    1. J Clin Microbiol. 1991 May;29(5):901-5 - PubMed

Publication types

LinkOut - more resources