Liquid chromatography with electrochemical detection for quantitation of bound choline liberated by phospholipase D hydrolysis from phospholipids containing choline in rat plasma
- PMID: 8376514
- DOI: 10.1016/0378-4347(93)80402-p
Liquid chromatography with electrochemical detection for quantitation of bound choline liberated by phospholipase D hydrolysis from phospholipids containing choline in rat plasma
Abstract
This report describes the optimal conditions for the determination of bound choline in rat plasma. The method used was based on the liberation of choline by phospholipase D from phospholipids containing choline in plasma, followed by high-performance liquid chromatographic analysis. Normal concentrations of total, free and bound choline in rat plasma were found to be 1278.7 +/- 132.5, 11.5 +/- 2.2 and 1267.2 +/- 125.5 nmol/ml, respectively. The described procedure has the advantages of rapidity, specificity, excellent precision and the need for only a small amount of the sample.
Similar articles
-
Measurement of dietary choline-phospholipid content by a novel phospholipase D-triiodide method.J Nutr Sci Vitaminol (Tokyo). 2006 Feb;52(1):79-81. doi: 10.3177/jnsv.52.79. J Nutr Sci Vitaminol (Tokyo). 2006. PMID: 16637235
-
A new enzymatic method for determination of serum choline-containing phospholipids.Clin Chim Acta. 1977 Aug 15;79(1):93-8. doi: 10.1016/0009-8981(77)90465-x. Clin Chim Acta. 1977. PMID: 890967
-
Determination of acetylcholine and choline in microdialysates from spinal cord of rat using liquid chromatography with electrochemical detection.J Chromatogr. 1987 Dec 25;423:85-91. doi: 10.1016/0378-4347(87)80330-4. J Chromatogr. 1987. PMID: 3443679
-
[Quantitative determination of phospholipids in human blood and organs].Rinsho Byori. 1972;19:Suppl:94-111. Rinsho Byori. 1972. PMID: 4553532 Review. Japanese. No abstract available.
-
Intracellular signaling by hydrolysis of phospholipids and activation of protein kinase C.Science. 1992 Oct 23;258(5082):607-14. doi: 10.1126/science.1411571. Science. 1992. PMID: 1411571 Review.
Cited by
-
Assay of Phospholipase D Activity by an Amperometric Choline Oxidase Biosensor.Sensors (Basel). 2020 Feb 27;20(5):1304. doi: 10.3390/s20051304. Sensors (Basel). 2020. PMID: 32121031 Free PMC article.
-
Enhanced Electrocatalytic Detection of Choline Based on CNTs and Metal Oxide Nanomaterials.Molecules. 2021 Oct 28;26(21):6512. doi: 10.3390/molecules26216512. Molecules. 2021. PMID: 34770919 Free PMC article. Review.