A simplified method of "hypothetical grain" analysis of electron microscope autoradiographs
- PMID: 839062
- DOI: 10.1177/25.3.839062
A simplified method of "hypothetical grain" analysis of electron microscope autoradiographs
Abstract
An improved method for the analysis of high resolution electron microscope autoradiographs is described which is simple and quick to perform. The method uses a transparent screen superimposed over the autoradiograph prints to provide information on the distribution of grains over neighboring structures, produced by radioactive disintegrations occurring in different regions of the section. This "cross-scatter" information is used to estimate the radioactivity in different structures without the need to make any assumptions about the size, shape and arrangement of the structures within the autoradiographs being analyzed. The method allows activity in membranes and other linear structures to be determined and also the accuracy attributable to the activity values obtained.
Similar articles
-
Resolution of electron microscope autoradiography. IV. Application to analysis of autoradiographs.J Cell Biol. 1978 Jan;76(1):127-45. doi: 10.1083/jcb.76.1.127. J Cell Biol. 1978. PMID: 618890 Free PMC article.
-
Quantitative electron microscope autoradiography: application of multiple linear regression analysis.J Microsc. 1986 Oct;144(Pt 1):83-104. doi: 10.1111/j.1365-2818.1986.tb04675.x. J Microsc. 1986. PMID: 2432272
-
A new method for analyzing electron microscope autoradiographs using hypothetical grain distributions.J Cell Biol. 1973 Apr;57(1):9-15. doi: 10.1083/jcb.57.1.9. J Cell Biol. 1973. PMID: 4691396 Free PMC article.
-
[Modern methods of analyzing electron microscope autoradiograms in research at the subcellular level].Tsitologiia. 1981 Dec;23(12):1339-52. Tsitologiia. 1981. PMID: 7036485 Review. Russian.
-
[Calibration of the emulsion layers in quantitative electron microscopic autoradiography].Tsitologiia. 1978 Nov;20(11):1338-40. Tsitologiia. 1978. PMID: 366839 Review. Russian.
Cited by
-
Quantitative assessment of GABA-uptake sites in the neural lobe by electron-microscopic autoradiography.Cell Tissue Res. 1985;241(3):581-4. doi: 10.1007/BF00214578. Cell Tissue Res. 1985. PMID: 2992795
-
Reversible peritubular binding of a cationic protein (lysozyme) to flounder kidney tubules.Cell Tissue Res. 1978 Nov 20;194(2):207-18. doi: 10.1007/BF00220389. Cell Tissue Res. 1978. PMID: 728961
-
Uptake of [3H]threonine in human colonic mucosa associated with carcinoma: an autoradiographic analysis at the ultrastructural level.Histochem J. 1982 May;14(3):385-401. doi: 10.1007/BF01011851. Histochem J. 1982. PMID: 6811506
-
Autoradiographic study of the distribution of [3H]- and [14C]-hydrallazine in the rat.Br J Pharmacol. 1985 Jan;84(1):107-20. Br J Pharmacol. 1985. PMID: 3978307 Free PMC article.
-
Uptake of tritiated uteroglobin by the endometrium of the rabbit during peri-implantation.Cell Tissue Res. 1990 Mar;259(3):519-28. doi: 10.1007/BF01740779. Cell Tissue Res. 1990. PMID: 2317844
MeSH terms
LinkOut - more resources
Full Text Sources