Contamination of bronchoscopes with Mycobacterium tuberculosis
- PMID: 8400340
Contamination of bronchoscopes with Mycobacterium tuberculosis
Abstract
Difficulties with disinfection of endoscopes and reports of cross-contamination of bronchoscopy specimens have previously been described. A recent episode of mycobacterial cross-contamination of bronchoscopy specimens was identified in a tertiary care referral centre. Two of eight bronchoscope suction valves cultured positive for Mycobacterium tuberculosis and the cause of the outbreak was traced to a faulty wash/disinfect switch in an automatic washer. The situation was resolved following autoclaving of all suction valves and repair of the endoscope washer. This report highlights the problems with instrument design and supports previous recommendations to autoclave suction valves routinely after each use.
Similar articles
-
Bronchopulmonary cross-colonization and infection related to mycobacterial contamination of suction valves of bronchoscopes.J Infect Dis. 1989 May;159(5):954-8. doi: 10.1093/infdis/159.5.954. J Infect Dis. 1989. PMID: 2708844
-
Audit of bronchoscope disinfection: a survey of procedures in England and Wales and incidents of mycobacterial contamination.J Hosp Infect. 1994 Apr;26(4):301-8. doi: 10.1016/0195-6701(94)90022-1. J Hosp Infect. 1994. PMID: 7915292
-
A pseudoepidemic of Mycobacterium chelonae: contamination of a bronchoscope and autocleaner.Aust N Z J Med. 1994 Dec;24(6):693-5. doi: 10.1111/j.1445-5994.1994.tb01785.x. Aust N Z J Med. 1994. PMID: 7717921
-
[Prevention of infection transmitted by bronchial fibroscopes].Rev Pneumol Clin. 2001 Apr;57(2):67-72. Rev Pneumol Clin. 2001. PMID: 11353912 Review. French.
-
Transmission of infection by gastrointestinal endoscopy and bronchoscopy.Ann Intern Med. 1993 Jan 15;118(2):117-28. doi: 10.7326/0003-4819-118-2-199301150-00008. Ann Intern Med. 1993. PMID: 8416308 Review.
Cited by
-
Evaluation of reprocessing medical devices in 14 German regional hospitals and at 27 medical practitioners' offices within the European context - consequences for European harmonization.GMS Hyg Infect Control. 2013 Nov 6;8(2):Doc20. doi: 10.3205/dgkh000220. eCollection 2013. GMS Hyg Infect Control. 2013. PMID: 24327946 Free PMC article.
-
Evidence-based spectrum of antimicrobial activity for disinfection of bronchoscopes.J Hosp Infect. 2008 Oct;70 Suppl 1:60-8. doi: 10.1016/S0195-6701(08)60014-6. J Hosp Infect. 2008. PMID: 18994685 Free PMC article.
-
Identification of a contaminating Mycobacterium tuberculosis strain with a transposition of an IS6110 insertion element resulting in an altered spoligotype.J Clin Microbiol. 2001 Mar;39(3):1092-6. doi: 10.1128/JCM.37.3.1092-1096.2001. J Clin Microbiol. 2001. PMID: 11230432 Free PMC article.
-
American College of Chest Physicians and American Association for Bronchology [corrected] consensus statement: prevention of flexible bronchoscopy-associated infection.Chest. 2005 Sep;128(3):1742-55. doi: 10.1378/chest.128.3.1742. Chest. 2005. PMID: 16162783 Free PMC article. Review. No abstract available.
-
Chemical disinfection in healthcare settings: critical aspects for the development of global strategies.GMS Hyg Infect Control. 2020 Dec 23;15:Doc36. doi: 10.3205/dgkh000371. eCollection 2020. GMS Hyg Infect Control. 2020. PMID: 33520601 Free PMC article.
MeSH terms
LinkOut - more resources
Medical