Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug
- PMID: 8408156
- DOI: 10.2106/00004623-199309000-00010
Reduction of postoperative blood loss after press-fit condylar knee arthroplasty with use of a femoral intramedullary plug
Abstract
In a prospective study of eighty press-fit condylar knee arthroplasties performed with cement, we compared the postoperative blood loss in forty patients in whom the defect left by the femoral intramedullary alignment rod had been left open with the blood loss in forty patients in whom the defect had been closed with a plug of cement. The patients in the open-defect group had significantly more blood loss (mean, 1002 milliliters) in the first twenty-four hours after the operation than the closed-defect group (mean, 752 milliliters) (p < or = 0.01). The total postoperative blood loss was also significantly greater in the open-defect group (mean, 1536 milliliters) than in the closed-defect group (mean, 1215 milliliters) (p = 0.02).
Similar articles
-
Sealing the intramedullary femoral canal with autologous bone plug in total knee arthroplasty.J Arthroplasty. 2003 Jan;18(1):6-9. doi: 10.1054/arth.2003.50001. J Arthroplasty. 2003. PMID: 12555175
-
The influence of femoral cementing on perioperative blood loss in total knee arthroplasty: a prospective randomized study.J Bone Joint Surg Am. 2010 Mar;92(3):536-41. doi: 10.2106/JBJS.H.01159. J Bone Joint Surg Am. 2010. PMID: 20194310 Clinical Trial.
-
Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss.J Arthroplasty. 2000 Oct;15(7):947-9. doi: 10.1054/arth.2000.8592. J Arthroplasty. 2000. PMID: 11061459 Clinical Trial.
-
Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials.J Orthop Surg Res. 2017 Jun 5;12(1):82. doi: 10.1186/s13018-017-0582-3. J Orthop Surg Res. 2017. PMID: 28583144 Free PMC article.
-
Porous-coated anatomic total knee arthroplasty. A prospective analysis comparing cemented and cementless fixation.Clin Orthop Relat Res. 1991 Jun;(267):128-36. Clin Orthop Relat Res. 1991. PMID: 2044263 Review.
Cited by
-
Blood loss in total knee arthroplasty: an analysis of risk factors.Int Orthop. 2007 Feb;31(1):39-44. doi: 10.1007/s00264-006-0096-9. Epub 2006 Mar 28. Int Orthop. 2007. PMID: 16568327 Free PMC article.
-
The effect of total synovectomy in total knee arthroplasty: a prospective randomized controlled study.Knee Surg Sports Traumatol Arthrosc. 2011 Jun;19(6):932-5. doi: 10.1007/s00167-010-1270-6. Epub 2010 Oct 2. Knee Surg Sports Traumatol Arthrosc. 2011. PMID: 20890699 Clinical Trial.
-
A New Concept of Using Femoral Condyles Surface for Femoral Component Alignment During Total Knee Arthroplasty: A Technical Note.Indian J Orthop. 2023 Nov 15;57(12):2088-2094. doi: 10.1007/s43465-023-01023-0. eCollection 2023 Dec. Indian J Orthop. 2023. PMID: 38009183 Free PMC article.
-
Comparison of three methods for sealing of the intramedullary femoral canal during total knee arthroplasty; a randomized controlled trial.Arch Orthop Trauma Surg. 2023 Jun;143(6):3309-3317. doi: 10.1007/s00402-022-04596-x. Epub 2022 Aug 26. Arch Orthop Trauma Surg. 2023. PMID: 36018367 Clinical Trial.
-
Asymmetric polyethylene inserts promote favorable kinematics and better clinical outcome compared to symmetric inserts in a mobile bearing total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2019 Apr;27(4):1096-1105. doi: 10.1007/s00167-018-5207-9. Epub 2018 Oct 10. Knee Surg Sports Traumatol Arthrosc. 2019. PMID: 30306242
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources