Prolonged intracorporeal support of gas exchange with an intravenacaval oxygenator
- PMID: 8417871
- DOI: 10.1378/chest.103.1.158
Prolonged intracorporeal support of gas exchange with an intravenacaval oxygenator
Abstract
Patients with severe respiratory failure undergoing conventional mechanical ventilation typically are exposed to levels of ventilator support that place the patient at risk of barotrauma or oxygen toxicity. In severe cases, gas exchange may be inadequate despite maximal ventilator support. We report two cases of advanced respiratory failure in which augmentation of gas exchange was provided for prolonged periods (18 and 13 days) with an intravenacaval hollow-fiber membrane oxygenator (IVOX). Following implantation, significant reductions in ventilator support were possible with improvement in arterial blood gas values. No significant complications were noted. IVOX can provide clinically useful augmentation of gas exchange in respiratory failure and can be used for prolonged periods.
Comment in
-
Intracorporeal respiratory support. A potential supplement to airway pressure therapy?Chest. 1993 Jan;103(1):1-2. doi: 10.1378/chest.103.1.1. Chest. 1993. PMID: 8417860 No abstract available.
Similar articles
-
In vivo gas transfer performance of the intravascular oxygenator in acute respiratory failure.Artif Organs. 1994 Nov;18(11):840-5. doi: 10.1111/j.1525-1594.1994.tb03333.x. Artif Organs. 1994. PMID: 7864734
-
Intravenacaval membrane oxygenation and carbon dioxide removal in severe acute respiratory failure.Chest. 1995 Jun;107(6):1689-97. doi: 10.1378/chest.107.6.1689. Chest. 1995. PMID: 7781369
-
Intravascular membrane oxygenation and carbon dioxide removal with IVOX: can improved design and permissive hypercapnia achieve adequate respiratory support during severe respiratory failure?Artif Organs. 1994 Nov;18(11):833-9. doi: 10.1111/j.1525-1594.1994.tb03332.x. Artif Organs. 1994. PMID: 7864733
-
Intravascular gas exchange.Monaldi Arch Chest Dis. 1999 Feb;54(1):38-42. Monaldi Arch Chest Dis. 1999. PMID: 10218369 Review.
-
[Present status of IVOX device].Rinsho Kyobu Geka. 1994 Dec;14(6):461-4. Rinsho Kyobu Geka. 1994. PMID: 9423123 Review. Japanese.
Cited by
-
Reduction of ventilator settings allowed by intravenous oxygenator (IVOX) in ARDS patients.Intensive Care Med. 1995 Jan;21(1):11-7. doi: 10.1007/BF02425148. Intensive Care Med. 1995. PMID: 7560467 Clinical Trial.
-
ARDS and sepsis--definitions and new therapy.Can J Anaesth. 1993 Jul;40(7):585-90. doi: 10.1007/BF03009692. Can J Anaesth. 1993. PMID: 8403131 English, French. No abstract available.
-
Exogenous female sex steroid hormones and risk of asthma and asthma-like symptoms: a cross sectional study of the general population.Thorax. 2001 Aug;56(8):613-6. doi: 10.1136/thorax.56.8.613. Thorax. 2001. PMID: 11462063 Free PMC article.
-
Effect of impeller design and spacing on gas exchange in a percutaneous respiratory assist catheter.Artif Organs. 2014 Dec;38(12):1007-17. doi: 10.1111/aor.12308. Epub 2014 Apr 22. Artif Organs. 2014. PMID: 24749994 Free PMC article.
-
Supporting the injured lung.BMJ. 1993 Nov 20;307(6915):1293-4. doi: 10.1136/bmj.307.6915.1293. BMJ. 1993. PMID: 8257877 Free PMC article. No abstract available.