Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 1993 Feb 15;118(4):282-9.
doi: 10.7326/0003-4819-118-4-199302150-00007.

Fine-needle aspiration biopsy of the thyroid: an appraisal

Affiliations
Review

Fine-needle aspiration biopsy of the thyroid: an appraisal

H Gharib et al. Ann Intern Med. .

Abstract

Objective: To review the literature on the utility of fine-needle aspiration biopsy in the diagnostic management of nodular thyroid disease.

Data sources: Relevant articles published in major English-language medical journals during the last 10 years.

Data extraction: Articles were reviewed to assess the results of fine-needle aspiration biopsy and its effect on thyroid management and cost of care.

Data synthesis: Fine-needle aspiration biopsy of the thyroid gland is safe, inexpensive, minimally invasive, and highly accurate in the diagnosis of nodular thyroid disease. Four cytologic diagnostic categories are used. Rates for these categories, based on data pooled from seven series, were as follows: benign, 69%; suspicious, 10%; malignant, 4%; and nondiagnostic, 17%. Analysis of recent data suggests a false-negative rate of 1% to 11%, a false-positive rate of 1% to 8%, a sensitivity of 65% to 98%, and a specificity of 72% to 100%. Limitations of fine-needle aspiration are related to the skill of the aspirator, the expertise of the cytologist, and the difficulty in distinguishing some benign cellular adenomas from their malignant counterparts. The introduction of fine-needle aspiration has had a substantial effect on the management of patients with thyroid nodules. The percentage of patients undergoing thyroidectomy has decreased by 25%, and the yield of carcinoma in patients who undergo surgery has increased from 15% to at least 30%. Fine-needle aspiration has decreased the cost of care by 25%.

Conclusions: Fine-needle aspiration biopsy is safe, accurate, and cost-effective. The procedure has a central role in the management of thyroid nodules and should be used as the initial diagnostic test.

PubMed Disclaimer

Comment in

  • Management of thyroid nodules.
    Daniels GH. Daniels GH. Ann Intern Med. 1993 Oct 1;119(7 Pt 1):634. doi: 10.7326/0003-4819-119-7_part_1-199310010-00019. Ann Intern Med. 1993. PMID: 8363179 No abstract available.

LinkOut - more resources