Late results of valve replacement with the Björk-Shiley valve (1973 to 1982)
- PMID: 8429659
Late results of valve replacement with the Björk-Shiley valve (1973 to 1982)
Abstract
Cardiac valve replacement with use of only the Björk-Shiley prosthesis was performed in 1253 patients between January 1973 and December 1982. There were 828 patients having aortic valve replacement, 280 patients having mitral valve replacement, and 145 patients having double valve replacement with aortic and mitral valve prostheses. Patient outcome was stratified according to multiple variables, including valve position and valve model (spherical versus convexo-concave discs). No valve failure due to strut fracture was identified in 26 high-risk patients (mitral valve replacement with greater than or equal to 29 mm implanted in patients less than or equal to 50 years of age) followed up for a mean of 10 years postoperatively. Fifteen patients had late thrombosis of their Björk-Shiley prosthesis (0.28 per 100 patient-years), but there was no significant difference in risk of valve thrombosis comparing the spherical and convexo-concave discs (0.27 per 100 patient-years versus 0.27 per 100 patient-years). One hundred two patients had 128 thromboembolic episodes; rates of thromboembolism after aortic valve replacement, mitral valve replacement, and double valve replacement were 2.1, 4.3, and 4.6 per 100 patient-years, respectively. Percentages of patients free from thromboemboli after aortic valve replacement, mitral valve replacement, and double valve replacement were 93% +/- 1%, 86% +/- 2%, and 89% +/- 3% at 5 years postoperatively and 87% +/- 2%, 79% +/- 5%, and 77% +/- 8% 10 years postoperatively. There was no significant difference in the rates of thromboemboli for spherical and convexo-concave discs for all patients and for each of the subgroups. Ten-year actuarial survival estimates for patients dismissed alive from the hospital after aortic valve replacement, mitral valve replacement, and double valve replacement with the Björk-Shiley valve were 65% +/- 4%, 63% +/- 5%, and 55% +/- 8%, respectively. Overall event-free survival (freedom from death, thromboembolism, anticoagulant-related bleeding, endocarditis, and reoperation) was similar for the three patient groups. Performance of the Björk-Shiley valve as judged by late patient follow-up is similar to other mechanical valves, and modifications in disc design do not appear to have reduced the threat of late valve thrombosis and thromboemboli. Evidence does not support elective explantation of this prosthesis.
Comment in
-
Valve thrombosis and strut fracture with the Björk-Shiley valve.J Thorac Cardiovasc Surg. 1994 Jul;108(1):177-9. J Thorac Cardiovasc Surg. 1994. PMID: 8028365 No abstract available.
Similar articles
-
Fourteen years' experience with the Björk-Shiley tilting disc prosthesis.J Thorac Cardiovasc Surg. 1986 Mar;91(3):350-61. J Thorac Cardiovasc Surg. 1986. PMID: 3951241
-
Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Björk-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement.J Thorac Cardiovasc Surg. 1986 Feb;91(2):174-83. J Thorac Cardiovasc Surg. 1986. PMID: 3945084
-
[Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].Z Kardiol. 1983 May;72(5):251-61. Z Kardiol. 1983. PMID: 6880335 German.
-
[Long-term results over 20 years of aortic valve replacement with the standard Björk-Shiley prosthesis].Arch Mal Coeur Vaiss. 1996 Sep;89(9):1137-43. Arch Mal Coeur Vaiss. 1996. PMID: 8952837 Review. French.
-
[Late results of isolated aortic valve replacement by Björk-Shiley prosthesis. Apropos of 596 cases].Arch Mal Coeur Vaiss. 1991 Jan;84(1):47-54. Arch Mal Coeur Vaiss. 1991. PMID: 2012485 Review. French.
Cited by
-
Long-term experience with the Bjork-Shiley Monostrut tilting disc valve.J Korean Med Sci. 2007 Dec;22(6):1060-4. doi: 10.3346/jkms.2007.22.6.1060. J Korean Med Sci. 2007. PMID: 18162723 Free PMC article.