Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer
- PMID: 8432019
Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer
Abstract
We evaluated a novel system designed for rapid, point-of-care measurement of sodium, potassium, chloride, urea nitrogen, glucose, and hematocrit. The i-STAT Portable Clinical Analyzer (PCA) system is composed of a hand-held analyzer and disposable cartridges. Sample analysis takes place in the cartridge, which contains a series of thin-film electrodes microfabricated on silicon chips. The PCA was evaluated for precision, accuracy, and utility in emergency department and stat laboratory settings. Precision did not differ significantly between these two locations, the CVs being as follows: sodium, 0.46-0.89%; potassium, 1.06-1.45%; chloride, 0.69-2.76%; urea nitrogen, 2.54-6.12%; and glucose, 4.39-5.19%. The assessment of accuracy was based on comparison of patients' sample values analyzed by the PCA and the Kodak Ektachem 700 (or the Coulter ST for hematocrit). Regression statistics were acceptable for all analytes except chloride, for which the regression data were influenced by the limited range of results. A difference plot of the chloride comparison showed that the bias rarely exceeded 5 mmol/L. Mean hematocrit values significantly differed between the PCA and the Coulter ST, apparently because of different calibration procedures.
Similar articles
-
Evaluation of the i-STAT system: a portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose, and hematocrit.Clin Biochem. 1995 Apr;28(2):187-92. doi: 10.1016/0009-9120(95)90708-6. Clin Biochem. 1995. PMID: 7628079
-
Evaluation of i-STAT portable clinical analyzer in a hemodialysis unit.Clin Biochem. 1996 Apr;29(2):117-24. doi: 10.1016/0009-9120(96)02028-0. Clin Biochem. 1996. PMID: 8601319
-
Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.Ann Clin Lab Sci. 2002 Summer;32(3):231-43. Ann Clin Lab Sci. 2002. PMID: 12175085
-
Establishment of blood analyte intervals for laboratory mice and rats by use of a portable clinical analyzer.J Am Assoc Lab Anim Sci. 2007 May;46(3):47-52. J Am Assoc Lab Anim Sci. 2007. PMID: 17487953
-
Evaluation of a portable clinical analyzer in cynomolgus Macaques (Macaca fasicularis).J Am Assoc Lab Anim Sci. 2007 May;46(3):53-7. J Am Assoc Lab Anim Sci. 2007. PMID: 17487954
Cited by
-
Body Mass Changes Across a Variety of Running Race Distances in the Tropics.Sports Med Open. 2016 Jul 19;2(1):26. doi: 10.1186/s40798-016-0050-3. eCollection 2015 Jun. Sports Med Open. 2016. PMID: 27478761 Free PMC article.
-
Implantable nanosensors: toward continuous physiologic monitoring.Anal Chem. 2014 Feb 4;86(3):1314-23. doi: 10.1021/ac402688k. Epub 2013 Dec 10. Anal Chem. 2014. PMID: 24325255 Free PMC article. Review.
-
Chip PCR. I. Surface passivation of microfabricated silicon-glass chips for PCR.Nucleic Acids Res. 1996 Jan 15;24(2):375-9. doi: 10.1093/nar/24.2.375. Nucleic Acids Res. 1996. PMID: 8628665 Free PMC article.
-
The Effect of Moment of Inertia on the Liquids in Centrifugal Microfluidics.Micromachines (Basel). 2016 Dec 2;7(12):215. doi: 10.3390/mi7120215. Micromachines (Basel). 2016. PMID: 30404391 Free PMC article.
-
Droplet-Based Measurements of DNA-Templated Nanoclusters-Towards Point-of-Care Applications.Biosensors (Basel). 2025 Jul 1;15(7):417. doi: 10.3390/bios15070417. Biosensors (Basel). 2025. PMID: 40710067 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources