Phase-resolved fluorescence lifetime measurements for flow cytometry
- PMID: 8440147
- DOI: 10.1002/cyto.990140204
Phase-resolved fluorescence lifetime measurements for flow cytometry
Abstract
A flow cytometer capable of measuring fluorescence lifetimes by the phase shift method has been built and evaluated. Under optimal conditions, the resolution of the fluorescence lifetime measurement is shown to be under 200 picoseconds. Pulse intensity variations are normalized using limiting amplifiers and electronic filtering. Normalization of signal intensities provides a lifetime measurement that is independent of fluorescence intensity over at least a 50-fold (17 dB) range in fluorescence intensity. The fluorescence lifetimes of unbound dye, fluorescent beads, cells stained with ethidium bromide, propidium iodide, and phycoerythrin-conjugated monoclonal antibodies have been measured. The fluorescence lifetimes measured for these particles are well correlated with lifetime measurements made using a standard fluorimeter. Cells stained with ethidium bromide and propidium iodide at various nucleotide-to-dye ratios are shown to exhibit similar behavior to static cuvette measurements. The fluorescence lifetime parameter is also shown to resolve phycoerthyrin fluorescence from propidium iodide fluorescence.
Similar articles
-
Fluorescence lifetime-based discrimination and quantification of cellular DNA and RNA with phase-sensitive flow cytometry.Cytometry A. 2003 Mar;52(1):46-55. doi: 10.1002/cyto.a.10022. Cytometry A. 2003. PMID: 12596251
-
Interactions of intercalating fluorochromes with DNA analyzed by conventional and fluorescence lifetime flow cytometry utilizing deuterium oxide.Cytometry. 1996 Oct 1;25(2):164-72. doi: 10.1002/(SICI)1097-0320(19961001)25:2<164::AID-CYTO5>3.0.CO;2-H. Cytometry. 1996. PMID: 8891446
-
Resolution of fluorescence signals from cells labeled with fluorochromes having different lifetimes by phase-sensitive flow cytometry.Cytometry. 1993;14(2):210-6. doi: 10.1002/cyto.990140214. Cytometry. 1993. PMID: 8440154
-
Simultaneous measurement of two cellular antigens and DNA using fluorescein-isothiocyanate, R-phycoerythrin, and propidium iodide on a standard FACScan.Cytometry. 1994 Feb 1;15(2):117-28. doi: 10.1002/cyto.990150205. Cytometry. 1994. PMID: 8168399
-
[Comparison of 2 techniques for measuring lymphocyte proliferation: tritiated methyl-thymidine incorporation and propidium iodide fluorometry].Rev Med Brux. 1995 Nov;16(5):368-71. Rev Med Brux. 1995. PMID: 7501914 Review. French.
Cited by
-
Cytometric sorting based on the fluorescence lifetime of spectrally overlapping signals.Opt Express. 2013 Jun 17;21(12):14816-31. doi: 10.1364/OE.21.014816. Opt Express. 2013. PMID: 23787669 Free PMC article.
-
Emerging biomedical and advanced applications of time-resolved fluorescence spectroscopy.J Fluoresc. 1994 Mar;4(1):117-36. doi: 10.1007/BF01876666. J Fluoresc. 1994. PMID: 24233306
-
Phasor plotting with frequency-domain flow cytometry.Opt Express. 2016 Jun 27;24(13):14596-607. doi: 10.1364/OE.24.014596. Opt Express. 2016. PMID: 27410612 Free PMC article.
-
Analysis of Flow Cytometric Fluorescence Lifetime with Time-Delay Estimation of Pulse Signals.Sensors (Basel). 2018 Feb 3;18(2):442. doi: 10.3390/s18020442. Sensors (Basel). 2018. PMID: 29401636 Free PMC article.
-
Optical measurements of pH using fluorescence lifetimes and phase-modulation fluorometry.Anal Chem. 1993 Jul 1;65(13):1668-74. doi: 10.1021/ac00061a007. Anal Chem. 1993. PMID: 8368522 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous