Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1993 Feb;16(2):119-22.
doi: 10.1016/0732-8893(93)90005-r.

Species identification and determination of high-level aminoglycoside resistance among enterococci. Comparison study of sterile body fluid isolates, 1985-1991

Affiliations
Comparative Study

Species identification and determination of high-level aminoglycoside resistance among enterococci. Comparison study of sterile body fluid isolates, 1985-1991

B J Buschelman et al. Diagn Microbiol Infect Dis. 1993 Feb.

Abstract

Enterococcus spp. have become the third most common cause of nosocomial infections. High-level aminoglycoside resistance (HLR), an important clinical concern, has been associated with some species of the enterococci. We evaluated the Vitek and API 20S systems for species identification and the Vitek for the detection of HLR. Enterococci from nosocomial infections (208 strains) at the University of Iowa Hospital (1985-1991) were tested by Vitek, API 20S, and reference methods. The error rate for species identification was 6.7% for the API 20S and 5.8% for the Vitek Gram-positive identification (GPI) cards. Both systems tended to incorrectly identify other enterococcal species as Enterococcus faecium. HLR was found in Enterococcus faecalis and E. faecium isolates only. The highest rates of HLR to streptomycin alone (17.9%) and with gentamicin (13.5%) was observed among E. faecalis strains, and to gentamicin alone (7.3%) was found among E. faecium isolates. No apparent differences in HLR rates were found from year-to-year over the 7-year enterococcus sample interval. Susceptibility errors for Vitek were among the streptomycin tests only. Our results demonstrated acceptable performance by the Vitek cards for enterococcal species identification and the detection of HLR. API 20S also provided an acceptable ability to speciate the enterococci within its data base, however, both systems must be improved by adding other clinical important Enterococcus species.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources