Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1993 May;13(5):738-47.
doi: 10.1161/01.atv.13.5.738.

Intravenous and endobronchial administration of G4120, a cyclic Arg-Gly-Asp-containing platelet GPIIb/IIIa receptor-blocking pentapeptide, enhances and sustains coronary arterial thrombolysis with rt-PA in a canine preparation

Affiliations

Intravenous and endobronchial administration of G4120, a cyclic Arg-Gly-Asp-containing platelet GPIIb/IIIa receptor-blocking pentapeptide, enhances and sustains coronary arterial thrombolysis with rt-PA in a canine preparation

T Yasuda et al. Arterioscler Thromb. 1993 May.

Abstract

G4120, L-cysteine, N-(mercaptoacetyl)-D-tyrosyl-L-arginylglycyl-L-alpha- aspartyl-cyclic(1-->5)-sulfide, 5-oxide, a synthetic cyclic Arg-Gly-Asp-containing pentapeptide, has a high affinity (dissociation constant of 4 nM) for the platelet glycoprotein (GP) IIb/IIIa receptor. The effects of its intravenous or endobronchial administration on thrombolysis, reocclusion, and bleeding time prolongation induced with 0.45 mg/kg bolus injections of recombinant tissue-type plasminogen activator in combination with intravenous heparin (4,000-unit bolus and 1,000 units each hour) were studied in a canine model consisting of an erythrocyte-rich blood clot in the left anterior descending coronary artery. Coronary patency was monitored for 3 hours both by ultrasonic flow probe and by repeat coronary angiography. Four groups of six to 10 dogs were studied with intravenous infusions of 0, 0.1, 0.2, or 0.3 mg/kg G4120 over 60 minutes. G4120 at a dose of 0.3 mg/kg reduced the time to reflow from a mean control value of 45 to 8 minutes (p = 0.036) and delayed reocclusion (p = 0.001). Four groups of five or six dogs were studied with endobronchial instillation of G4120 in a randomized, blinded study design using 0, 0.13, 0.25, or 0.5 mg/kg G4120. Endobronchial G4120 at a dose of 0.5 mg/kg reduced the time to reflow from a mean control value of 52 to 7 minutes (p = 0.039) and abolished cyclic reocclusion and reflow (p = 0.008). G4120 induced a dose-related transient prolongation of the template bleeding time and inhibition of ADP-induced platelet aggregation. G4120, a synthetic low-molecular-weight GPIIb/IIIa inhibitor that may be produced by chemical synthesis, may be of clinical value as a conjunctive agent for thrombolysis in patients with ischemic coronary syndromes.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources