Wire chambers revisited
- PMID: 8491229
- DOI: 10.1007/BF00169813
Wire chambers revisited
Abstract
Detectors used for radioisotope imaging have, historically, been based on scintillating crystal/photomultiplier combinations in various forms. From the rectilinear scanner through to modern gamma cameras and positron cameras, the basic technology has remained much the same. Efforts to overcome the limitations of this form of technology have foundered on the inability to reproduce the required sensitivity, spatial resolution and sensitive area at acceptable cost. Multiwire proportional chambers (MWPCs) have long been used as position-sensitive charged particle detectors in nuclear and high-energy physics. MWPCs are large-area gas-filled ionisation chambers in which large arrays of fine wires are used to measure the position of ionisation produced in the gas by the passage of charged particles. The important properties of MWPCs are high-spatial-resolution, large-area, high-count-rate performance at low cost. For research applications, detectors several metres square have been built and small-area detectors have a charged particle resolution of 0.4 mm at a count rate of several million per second. Modification is required to MWPCs for nuclear medicine imaging. As gamma rays or X-rays cannot be detected directly, they must be converted into photo- or Compton scatter electrons. Photon-electron conversion requires the use of high atomic number materials in the body of the chamber. Pressurised xenon is the most useful form of "gas only" photon-electron convertor and has been used successfully in a gamma camera for the detection of gamma rays at energies below 100 keV. This camera has been developed specifically for high-count-rate first-pass cardiac imaging. This high-pressure xenon gas MWPC is the key to a highly competitive system which can outperform scintillator-based systems. The count rate performance is close to a million counts per second and the intrinsic spatial resolution is better than the best scintillator-based camera. The MWPC camera produces quantitative ejection fraction information of the highest quality. The detection of higher energy gamma rays has proved more problematical, needing a solid photon-electron convertor to be incorporated into the chamber. Several groups have been working on this problem with modest success so far. The only clinical detectors have been developed for positron emission tomography, where thin lead or lead-glass can provide an acceptable convertor for 511 keV photons. Two MWPC positron cameras have been evaluated clinically and one is now in routine use in clinical oncology. The problems of detection efficiency have not been solved by these detectors although reliability and large-area PET imaging have been proven.(ABSTRACT TRUNCATED AT 400 WORDS)
Similar articles
-
NaI gamma camera performance for high energies: Effects of crystal thickness, photomultiplier tube geometry and light guide thickness.Med Phys. 2024 Jul;51(7):4696-4708. doi: 10.1002/mp.17043. Epub 2024 Apr 3. Med Phys. 2024. PMID: 38569052
-
Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.Phys Med Biol. 2007 Jul 7;52(13):3753-72. doi: 10.1088/0031-9155/52/13/007. Epub 2007 May 29. Phys Med Biol. 2007. PMID: 17664575 Free PMC article.
-
Compton camera study for high efficiency SPECT and benchmark with Anger system.Phys Med Biol. 2017 Nov 9;62(23):8794-8812. doi: 10.1088/1361-6560/aa926a. Phys Med Biol. 2017. PMID: 28994664
-
The role of hybrid cameras in oncology.Semin Nucl Med. 2000 Oct;30(4):268-80. doi: 10.1053/snuc.2000.9541. Semin Nucl Med. 2000. PMID: 11105928 Review.
-
PET imaging using gamma camera systems: a review.Nucl Med Commun. 1996 Sep;17(9):758-66. doi: 10.1097/00006231-199609000-00006. Nucl Med Commun. 1996. PMID: 8895903 Review.
Cited by
-
Measurement of ventricular function with scintigraphic techniques: part I-imaging hardware, radiopharmaceuticals, and first-pass radionuclide angiography.J Nucl Cardiol. 2005 Jan-Feb;12(1):86-95. doi: 10.1016/j.nuclcard.2004.11.004. J Nucl Cardiol. 2005. PMID: 15682369 Review. No abstract available.
-
Development and validation of a novel technique for murine first-pass radionuclide angiography with a fast multiwire camera and tantalum 178.J Nucl Cardiol. 2001 Mar-Apr;8(2):171-81. doi: 10.1067/mnc.2001.112135. J Nucl Cardiol. 2001. PMID: 11295695
-
Imaging metastatic testicular germ cell tumours with 18FDG positron emission tomography: prospects for detection and management.Eur J Nucl Med. 1995 Jun;22(6):508-13. doi: 10.1007/BF00817273. Eur J Nucl Med. 1995. PMID: 7556294
-
Recent developments in PET detector technology.Phys Med Biol. 2008 Sep 7;53(17):R287-317. doi: 10.1088/0031-9155/53/17/R01. Epub 2008 Aug 11. Phys Med Biol. 2008. PMID: 18695301 Free PMC article. Review.
References
Publication types
MeSH terms
LinkOut - more resources
Research Materials