Multicellular dosimetry for beta-emitting radionuclides: autoradiography, thermoluminescent dosimetry and three-dimensional dose calculations
- PMID: 8492763
- DOI: 10.1118/1.597050
Multicellular dosimetry for beta-emitting radionuclides: autoradiography, thermoluminescent dosimetry and three-dimensional dose calculations
Abstract
Inhomogeneities in activity distributions over distances from 10 to 10(4) microns are observed in many tumors treated with radiolabeled antibodies. Resulting nonuniformities in absorbed dose may have consequences for the efficacy of radioimmunotherapy. Activity variations may be directly studied with quantitative autoradiography (ARG). Converting these data to absorbed dose distributions requires additional information about pharmacokinetics, the use of a point source function and consideration of the complete three-dimensional activity distribution, as obtained from sequential autoradiographic slices. Thermoluminescent dosimetry with specially prepared CaSO4:Dy dosimeters implanted into tissue can directly measure absorbed dose in selected regions. The conditions under which thermoluminescent dosimeters (TLD) are used differ markedly from "normal" use conditions in external beam radiotherapy. Therefore special calibration and quality assurance precautions are needed to assure the precision of this technique. Procedures and pitfalls in the use of both techniques in radioimmunotherapy are described.
Similar articles
-
Tumor dosimetry in radioimmunotherapy: methods of calculation for beta particles.Med Phys. 1993 Mar-Apr;20(2 Pt 2):529-34. doi: 10.1118/1.597048. Med Phys. 1993. PMID: 8492761 Review.
-
Thermoluminescent dosimeters (TLD-100) for absorbed dose measurements in alpha-emitting radionuclides.Appl Radiat Isot. 2024 Jun;208:111307. doi: 10.1016/j.apradiso.2024.111307. Epub 2024 Mar 29. Appl Radiat Isot. 2024. PMID: 38564840
-
Considerations on the calibration of small thermoluminescent dosimeters used for measurement of beta particle absorbed doses in liquid environments.Med Phys. 1993 Jul-Aug;20(4):1079-87. doi: 10.1118/1.597127. Med Phys. 1993. PMID: 8413016
-
Miniature thermoluminescent dosimeter absorbed dose measurements in tumor phantom models.J Nucl Med. 1986 Aug;27(8):1308-14. J Nucl Med. 1986. PMID: 3734904
-
Experimental radioimmunotherapy.Med Phys. 1993 Mar-Apr;20(2 Pt 2):551-67. doi: 10.1118/1.597142. Med Phys. 1993. PMID: 8492764 Review.
Cited by
-
Phantom validation of quantitative Y-90 PET/CT-based dosimetry in liver radioembolization.EJNMMI Res. 2017 Nov 28;7(1):94. doi: 10.1186/s13550-017-0341-9. EJNMMI Res. 2017. PMID: 29185067 Free PMC article.
-
Activity quantification and dosimetry in radiopharmaceutical therapy with reference to 177Lutetium.Front Nucl Med. 2024 Mar 28;4:1355912. doi: 10.3389/fnume.2024.1355912. eCollection 2024. Front Nucl Med. 2024. PMID: 39355215 Free PMC article. Review.
-
Radionuclide targeting and dosimetry at the microscopic level: the role of microautoradiography.Eur J Nucl Med. 1994 Dec;21(12):1347-65. doi: 10.1007/BF02426701. Eur J Nucl Med. 1994. PMID: 7875174 Review.
-
Radiation doses from 161Tb and 177Lu in single tumour cells and micrometastases.EJNMMI Phys. 2020 May 19;7(1):33. doi: 10.1186/s40658-020-00301-2. EJNMMI Phys. 2020. PMID: 32430671 Free PMC article.
-
Biodosimetry, can it find its way to the nuclear medicine clinic?Front Nucl Med. 2023 Jul 25;3:1209823. doi: 10.3389/fnume.2023.1209823. eCollection 2023. Front Nucl Med. 2023. PMID: 39355046 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources