Force generation by orthodontic coil springs
- PMID: 8498703
- DOI: 10.1043/0003-3219(1993)063<0145:FGBOCS>2.0.CO;2
Force generation by orthodontic coil springs
Abstract
Nickel titanium (NiTi) coil springs are a new development in orthodontics, designed to produce light continuous forces. This study compares the force delivery by NiTi open and closed coil springs during unloading (de-activation) to that provided by comparable stainless steel (SS) springs. Open-coil springs (0.010 x 0.035 inch) were compressed from their initial length of 15 mm to 6 mm and the forces generated with spring recovery recorded. Closed-coil springs (0.009 x 0.035 inch) were distracted from their initial length of 3 mm to 9 mm and the force recorded as the spring recovered. The closed-coil NiTi springs produced light continuous forces of 75-90 g over the distraction range of 6 mm while the open-coil springs produced forces of 55-70 g within the 9 mm compression range. SS springs produced heavier forces, ca. 200 g, for an activation of 1 mm and the generated force increased rapidly as the activation was increased. The findings indicate that NiTi coil springs deliver optimal forces for orthodontic tooth movement over a longer activation range than comparable SS springs.
Similar articles
-
An investigation of the forces used by clinicians to open spaces with coil springs.Aust Orthod J. 2006 Nov;22(2):115-20. Aust Orthod J. 2006. PMID: 17203574
-
An in vitro comparison of the force decay generated by different commercially available elastomeric chains and NiTi closed coil springs.Braz Oral Res. 2007 Jan-Mar;21(1):51-7. doi: 10.1590/s1806-83242007000100009. Braz Oral Res. 2007. PMID: 17384855
-
Force degradation of closed coil springs: an in vitro evaluation.Am J Orthod Dentofacial Orthop. 1992 Aug;102(2):127-33. doi: 10.1016/0889-5406(92)70024-5. Am J Orthod Dentofacial Orthop. 1992. PMID: 1636629
-
The effect of temperature change on the load value of Japanese NiTi coil springs in the superelastic range.Am J Orthod Dentofacial Orthop. 1996 Nov;110(5):553-8. doi: 10.1016/s0889-5406(96)70065-3. Am J Orthod Dentofacial Orthop. 1996. PMID: 8922516
-
The super-elastic Japanese NiTi alloy wire for use in orthodontics. Part III. Studies on the Japanese NiTi alloy coil springs.Am J Orthod Dentofacial Orthop. 1988 Aug;94(2):89-96. doi: 10.1016/0889-5406(88)90356-3. Am J Orthod Dentofacial Orthop. 1988. PMID: 3165245
Cited by
-
In-vivo force decay of nickel-titanium closed-coil springs.Am J Orthod Dentofacial Orthop. 2014 Apr;145(4):505-13. doi: 10.1016/j.ajodo.2013.12.023. Am J Orthod Dentofacial Orthop. 2014. PMID: 24703289 Free PMC article.
-
Effect of immersion in hydrochloric acid and sodium hypochlorite and autoclave sterilization on the force characteristics of orthodontic nickel-titanium open coils.Dent Res J (Isfahan). 2021 Feb 23;18:5. eCollection 2021. Dent Res J (Isfahan). 2021. PMID: 34084292 Free PMC article.
-
A comparison of maxillary canine retraction into healed and recent extraction sites using cone beam computed tomography: a randomized clinical trial.Angle Orthod. 2023 Jul 1;93(4):382-389. doi: 10.2319/110522-757.1. Angle Orthod. 2023. PMID: 37017438 Free PMC article. Clinical Trial.
-
Force-degradation pattern of six different orthodontic elastomeric chains.J Dent (Tehran). 2012 Fall;9(4):204-15. Epub 2012 Dec 31. J Dent (Tehran). 2012. PMID: 23323182 Free PMC article.
-
A Comparative Three-Dimensional Finite Element Study of Two Space Regainers in the Mixed Dentition Stage.Eur J Dent. 2020 Feb;14(1):107-114. doi: 10.1055/s-0040-1702254. Epub 2020 Mar 13. Eur J Dent. 2020. PMID: 32168538 Free PMC article.
Publication types
MeSH terms
Substances