Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1993 May;31(5):1088-94.
doi: 10.1128/jcm.31.5.1088-1094.1993.

Detection of Mycoplasma pneumoniae by polymerase chain reaction and nonradioactive hybridization in microtiter plates

Affiliations

Detection of Mycoplasma pneumoniae by polymerase chain reaction and nonradioactive hybridization in microtiter plates

E Lüneberg et al. J Clin Microbiol. 1993 May.

Abstract

In order to improve the diagnosis of a Mycoplasma pneumoniae infection, we developed a polymerase chain reaction (PCR)-based assay. The gene encoding elongation factor Tu (tuf) was selected as the target sequence. Oligonucleotides derived from variable stretches of the tuf gene were able to prime the amplification of a 950-bp fragment exclusively when M. pneumoniae DNA was used as the template. The sensitivity of the assay was increased 10-fold when the amplification products were hybridized with an internal M. pneumoniae-specific oligonucleotide. The use of three to four genome copies for PCR was sufficient for obtaining a hybridization signal. In addition, we substituted radioactive filter hybridization with a microtiter plate assay. Via a biotin moiety of one PCR primer, the amplification products were immobilized on streptavidin-coated microtiter plates. Subsequent hybridization with a digoxigenin-labeled oligonucleotide resulted in the same sensitivity and specificity as those obtained by filter hybridization. Clinical application of the assay was performed on 102 throat swab specimens from patients with respiratory tract infections. Of 21 culture-positive samples, 19 were confirmed to be positive in the PCR-based assay (sensitivity, 90%). Furthermore, 14 of 19 seropositive but culture-negative samples gave a positive hybridization signal. Of 62 culture-negative and seronegative specimens, 60 gave a negative result in our assay (specificity, 97%). Of the 33 samples that were positive in our PCR-based assay, 5 samples initially gave false-negative results because of the presence of inhibitory substances in those specimens. Inhibition of Taq polymerase in these five cases was prevented by an additional step of phenol extraction and subsequent ethanol precipitation.

PubMed Disclaimer

References

    1. Tex Rep Biol Med. 1965 Jun;23:Suppl 1:285+ - PubMed
    1. J Immunol. 1964 Jun;92:958-65 - PubMed
    1. Proc Natl Acad Sci U S A. 1977 Dec;74(12):5463-7 - PubMed
    1. J Biol Chem. 1980 Jan 25;255(2):728-34 - PubMed
    1. Gene. 1980 Dec;12(1-2):25-31 - PubMed

Publication types

MeSH terms

LinkOut - more resources