On the confounding effects of phosphor persistence in oscilloscopic displays
- PMID: 8506634
- DOI: 10.1016/0042-6989(93)90074-7
On the confounding effects of phosphor persistence in oscilloscopic displays
Abstract
Phosphor persistence has been a source of confounding in studies of temporal integration in vision. We examined the confounding by assessing the effects of the persistence of two commonly-used phosphors (P15 and P31) on performance of a temporal-integration task. In one experiment we eliminated the visibility of phosphor persistence by closing two mechanical shutters upon display termination. In a second experiment we estimated the duration of phosphor persistence by displaying the image behind closed shutters which opened upon display termination. No detectable persistence was every produced by P15 phosphor. By contrast, P31 phosphor produced persistence that lasted several hundred milliseconds even when a veiling light was projected on the screen. We ascribe the earlier instances of confounding to inadequate interpretation of the technical data on phosphor decay.
Comment in
-
On the measurement of phosphor persistence in oscilloscopic displays.Vision Res. 1994 Jun;34(12):1623. doi: 10.1016/0042-6989(94)90121-x. Vision Res. 1994. PMID: 7941371 No abstract available.