Comparison of root canal preparation using different automated devices and hand instrumentation
- PMID: 8509753
- DOI: 10.1016/S0099-2399(06)80509-1
Comparison of root canal preparation using different automated devices and hand instrumentation
Abstract
The pre- and postinstrumentation degree of curvatures in curved mesial root canals of mandibular molars were compared after preparation with eight automated devices and hand instrumentation. The straightening of the root canal was measured before preparation and after preparation to size 25 and 35. Procedural mistakes such as loss of working length or file fractures were also recorded. Following preparation to ISO 25, only the Endoplaner and the Canal Finder system showed significantly more straightening than hand instrumentation. After preparation to ISO 35, the Endoplaner and the Intra-Endo 3-LDSY showed significantly more straightening than hand instrumentation. Mecasonic, Excalibur, and the Canal Finder system also straightened the root canal more than hand instruments, but the results did not differ significantly. The best results with only moderate straightening and few cases of loss of working length were obtained by the Endolift and Giromatic handpieces, which both were comparable to hand instrumentation.
Similar articles
-
Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: a comparative SEM investigation.J Endod. 1997 May;23(5):301-6. doi: 10.1016/S0099-2399(97)80410-4. J Endod. 1997. PMID: 9545932
-
[Preparation of curved root canals using hand instruments and mechanical aids].Dtsch Zahnarztl Z. 1989 Jun;44(6):448-51. Dtsch Zahnarztl Z. 1989. PMID: 2630269 German.
-
A comparative study of root canal preparation with NiTi-TEE and K3 rotary Ni-Ti instruments.Int Endod J. 2006 Jan;39(1):71-80. doi: 10.1111/j.1365-2591.2005.01059.x. Int Endod J. 2006. PMID: 16409331 Clinical Trial.
-
[Canal Finder System 89!!! Improvements and indications after 4 years of experimentation and use].Rev Odontostomatol (Paris). 1990 Jul-Aug;19(4):327-36. Rev Odontostomatol (Paris). 1990. PMID: 2237106 Review. French.
-
[Basic techniques of root canal instrumentation].Av Odontoestomatol. 1991 Jan;7(1):41-8. Av Odontoestomatol. 1991. PMID: 2018611 Review. Spanish.
Cited by
-
The influence of the irrigant QMix on the push-out bond strength of a bioceramic endodontic sealer.Eur Oral Res. 2018 May;52(2):64-68. doi: 10.26650/eor.2018.446. Epub 2018 May 1. Eur Oral Res. 2018. PMID: 30775704 Free PMC article.
-
In Vitro Research Methods Used to Evaluate Shaping Ability of Rotary Endodontic Files-A Literature Review.Dent J (Basel). 2024 Oct 21;12(10):334. doi: 10.3390/dj12100334. Dent J (Basel). 2024. PMID: 39452462 Free PMC article. Review.
-
Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics.Bioact Mater. 2022 Sep 27;22:91-111. doi: 10.1016/j.bioactmat.2022.09.008. eCollection 2023 Apr. Bioact Mater. 2022. PMID: 36203965 Free PMC article.
-
Taper preparation variability compared to current taper standards using computed tomography.Int J Dent. 2012;2012:265695. doi: 10.1155/2012/265695. Epub 2012 Feb 29. Int J Dent. 2012. PMID: 22518136 Free PMC article.
-
Centering ability and dentin removal of rotary systems in curved root canals.Iran Endod J. 2009 Summer;4(3):91-5. Epub 2009 Jul 6. Iran Endod J. 2009. PMID: 24003328 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources