A solid-state arteriovenous oxygen difference analyzer for flowing whole blood
- PMID: 851207
- DOI: 10.1152/ajpheart.1977.232.4.H437
A solid-state arteriovenous oxygen difference analyzer for flowing whole blood
Abstract
This communication describes a spectrophotometric device which determines the arteriovenous oxygen difference (a-v O2) on whole blood flowing through optical cuvettes. The instrument consists entirely of commercially available solid-state components, including the light sources, light-emitting diodes. When calibrated against conventional determinations of blood oxygen content, the output of the a-v O2 analyzer was shown to be highly linear and to be independent of total hemoglobin concentration. The electronic circuit, the theory of the measurement, and sources of error are described in detail.
Similar articles
-
Continuous measurement of arteriovenous oxygen difference and VO2 by microcomputer.Am J Physiol. 1983 Jul;245(1):H178-82. doi: 10.1152/ajpheart.1983.245.1.H178. Am J Physiol. 1983. PMID: 6869559
-
Continuous spectrophotometric measurements of arteriovenous oxygen difference.J Appl Physiol. 1975 Jul;39(1):152-5. doi: 10.1152/jappl.1975.39.1.152. J Appl Physiol. 1975. PMID: 1150582
-
Arteriovenous oximeter for O2 content difference, O2 saturations, and hemoglobin content.Am J Physiol. 1989 Nov;257(5 Pt 2):H1712-6. doi: 10.1152/ajpheart.1989.257.5.H1712. Am J Physiol. 1989. PMID: 2589522
-
[The meaningfulness of central venous blood samples. Central venous versus mixed venous O2 status].Anaesthesist. 1991 Mar;40(3):131-44. Anaesthesist. 1991. PMID: 2035819 Review. German.
-
[Central venous blood gas analysis].G Ital Nefrol. 2015 Jan-Feb;32(1):gin/32.1.6. G Ital Nefrol. 2015. PMID: 25774583 Review. Italian.
Cited by
-
Effect of a bradycardic agent on the isolated blood-perfused canine heart.Cardiovasc Drugs Ther. 1991 Apr;5(2):481-8. doi: 10.1007/BF03029773. Cardiovasc Drugs Ther. 1991. PMID: 1854656 Review.
-
Gastrointestinal secretory, motor, circulatory, and metabolic effects of prosomatostatin.Proc Natl Acad Sci U S A. 1981 Mar;78(3):1967-71. doi: 10.1073/pnas.78.3.1967. Proc Natl Acad Sci U S A. 1981. PMID: 6112753 Free PMC article.
-
Hyperthyroid dog left ventricle has the same oxygen consumption versus pressure-volume area (PVA) relation as euthyroid dog.Heart Vessels. 1991;6(2):71-83. doi: 10.1007/BF02058752. Heart Vessels. 1991. PMID: 1830045
-
Force-time integral does not improve predictability of cardiac O2 consumption from pressure-volume area (PVA) in dog left ventricle.Heart Vessels. 1990;5(3):152-8. doi: 10.1007/BF02059910. Heart Vessels. 1990. PMID: 2361934
-
Ejecting activation differs in energetics from ordinary positive inotropism in the canine left ventricle.Heart Vessels. 1994;9(3):129-39. doi: 10.1007/BF01745238. Heart Vessels. 1994. PMID: 8056719
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources