Computed tomography pelvimetry: accuracy and radiation dose compared with conventional pelvimetry
- PMID: 8512510
- DOI: 10.1111/j.1440-1673.1993.tb00047.x
Computed tomography pelvimetry: accuracy and radiation dose compared with conventional pelvimetry
Abstract
Several publications in the past few years have indicated that computed tomography (CT) pelvimetry is preferable to conventional pelvimetry when considering accuracy and radiation dose. Many of the previous publications have, however, compared state of the art CT pelvimetry with outmoded conventional pelvimetry techniques. This study compared both the accuracy and the radiation dose of CT pelvimetry with conventional pelvimetry as practised in two large teaching obstetric hospitals in Melbourne. The study did not demonstrate any significant difference in the accuracy between the two methods. The radiation dose to the fetal gonads was also similar. The radiation dose using CT pelvimetry could be significantly lowered if the axial CT section through the ischial spines were excluded from the CT technique.
Similar articles
-
X-ray pelvimetry--which is the best technique?Clin Radiol. 1997 Feb;52(2):136-41. doi: 10.1016/s0009-9260(97)80107-9. Clin Radiol. 1997. PMID: 9043048
-
Can three-dimensional pelvimetry using low-dose stereoradiography replace low-dose CT pelvimetry?Diagn Interv Imaging. 2018 Sep;99(9):569-576. doi: 10.1016/j.diii.2018.02.008. Epub 2018 Mar 19. Diagn Interv Imaging. 2018. PMID: 29567122 Clinical Trial.
-
Low dose pelvimetry with biplane digital radiography.Acta Radiol. 1987 Sep-Oct;28(5):577-80. Acta Radiol. 1987. PMID: 2960351
-
[Methods, techniques and assessment criteria in obstetric pelvimetry].Z Geburtshilfe Perinatol. 1994 Mar-Apr;198(2):37-46. Z Geburtshilfe Perinatol. 1994. PMID: 8023529 Review. German.
-
[Computerized tomography pelvimetry: recent advances].Gynecol Obstet Fertil. 2003 May;31(5):465-70. doi: 10.1016/s1297-9589(03)00123-1. Gynecol Obstet Fertil. 2003. PMID: 14567127 Review. French.
Cited by
-
Pelvimetry by Three-Dimensional Computed Tomography in Non-Pregnant Multiparous Women Who Delivered Vaginally.Pol J Radiol. 2016 May 8;81:219-27. doi: 10.12659/PJR.896380. eCollection 2016. Pol J Radiol. 2016. PMID: 27231494 Free PMC article.
-
Intra- and inter-rater reliability in a comparative study of cross-sectional and spiral computed tomography pelvimetry methods.Acta Radiol Open. 2019 Jun 11;8(6):2058460119855187. doi: 10.1177/2058460119855187. eCollection 2019 Jun. Acta Radiol Open. 2019. PMID: 31218082 Free PMC article.
-
Pelvimetry for fetal cephalic presentations at or near term for deciding on mode of delivery.Cochrane Database Syst Rev. 2017 Mar 30;3(3):CD000161. doi: 10.1002/14651858.CD000161.pub2. Cochrane Database Syst Rev. 2017. PMID: 28358979 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous