Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1993 May;40(5 Pt 1):440-3.
doi: 10.1007/BF03009514.

Vital capacity rapid inhalation induction technique: comparison of sevoflurane and halothane

Affiliations
Clinical Trial

Vital capacity rapid inhalation induction technique: comparison of sevoflurane and halothane

M Yurino et al. Can J Anaesth. 1993 May.

Abstract

Induction of anaesthesia using the vital capacity rapid inhalation induction (VCRII) technique with either sevoflurane or halothane was compared. The induction time, characteristics, and acceptability were assessed. Thirty-two volunteers were given one of the vapours: 17 received sevoflurane and 15 halothane. Subjects were unpremedicated and breathed approximately 2.6 x minimum alveolar concentration (MAC) equivalent of either agent. There were no differences in the patients' cardiovascular or respiratory variables. The mean time for induction of anaesthesia with halothane (153 +/- 46 sec, SD) was slower than with sevoflurane (81 +/- 22 sec, SD, P < 0.05), reflecting its higher blood:gas solubility. There were fewer induction complications such as coughing and movement in the sevoflurane than in the halothane group. Subjects in the sevoflurane group found the smell of anaesthetic more acceptable than those in the halothane group (65% vs 13%, respectively). Subjects in both groups had no objection to undergoing the procedure again. It is concluded that both halothane and sevoflurane are effective in VCRII of anaesthesia without premedication. However, the slower speed of induction with halothane frustrated the anaesthetist because of the longer induction time, and may increase the chance of pronounced excitatory phenomena occurring.

PubMed Disclaimer

References

    1. Anaesthesia. 1986 May;41(5):472-6 - PubMed
    1. Lancet. 1986 Jul 12;2(8498):84 - PubMed
    1. Anesthesiology. 1987 Oct;67(4):584-7 - PubMed
    1. Proc R Soc Med. 1954 Jun;47(6):416-22 - PubMed
    1. Br J Anaesth. 1987 Oct;59(10):1214-8 - PubMed

LinkOut - more resources