Clinical Trial
. 1995 Aug;16(3 Suppl A):A161-73.
doi: 10.1088/0967-3334/16/3a/016.

Changes in the thoracic impedance distribution under different ventilatory conditions

Affiliations
Clinical Trial

Changes in the thoracic impedance distribution under different ventilatory conditions

G Hahn et al. Physiol Meas. 1995 Aug.

Abstract

The present study was performed with the aim of checking the suitability of EIT in imaging regional thoracic impedance variations during lung ventilation under predefined conditions and to compare EIT with established reference techniques. A new technique of functional EIT imaging designed to visualize physiologically relevant information from the sequentially registered series of thoracic distributions was introduced. Experiments were performed on five spontaneously breathing healthy subjects and on 12 anaesthetized supine pigs. 16 electrodes were placed around the thorax and consecutive transthoracic impedance distributions were measured at a rate of 1 Hz (Sheffield APT system mark I, IBEES, Sheffield, UK). Several voluntary breathing manoeuvres were performed in human subjects and the tracings of local impedance were compared with standard spirometry. In animal experiments EIT was applied during artificial ventilation at different ventilation rates and during stepwise passive emptying and filling of either one or both lungs while the respiratory muscles were relaxes. Further, selective blockade of lung regions resulting in regionally reduced ventilation was performed and the capability of EIT to follow and differentiate local ventilatory disturbances was checked by reference techniques (x-ray and staining methods). The experiments revealed an overall agreement between the spirometric and impedance data in all breathing patterns performed. A linear relationship between changes of the air content of the lungs and the regional thoracic impedance was shown (intraindividual correlation coefficient range, 0.986-0.999; n = 12 animals). The functional images of the impedance distribution across the thorax reproduced adequately the typical anatomical characteristics of the pig and the human thorax. The spatial resolution of EIT functional images was sufficient to differentiate lung areas corresponding to approximately 20 ml tissue volume. EIT with the additional evaluation procedure of functional imaging was shown to be a suitable and reliable method of imaging different ventilatory conditions with the potential to become a useful tool for monitoring respiratory function.