A modified method of simultaneous bone grafting and placement of endosseous implants in the severely atrophic maxilla
- PMID: 8530170
A modified method of simultaneous bone grafting and placement of endosseous implants in the severely atrophic maxilla
Abstract
The purpose of this investigation was to clinically evaluate the modified method for surgical rehabilitation of severely atrophied maxillae with titanium implants. In 35 patients, sinus lift, Le Fort I osteotomy, and a downtilting of the maxilla were performed. Bone grafts from the iliac crest, placed between the sinus mucosa and the sinus floor, were secured with three to four Bränemark titanium implants 10 to 20 mm in length on each side. The osteotomized maxilla was stabilized with miniplates. The observation period was between 1 and 4 years after abutment connection. The rate of successful osseointegration was 86.6%.
Similar articles
-
Root-form implant placement and bone-graft reconstruction correct severely atrophied maxillae.Dent Implantol Update. 1994 Aug;5(8):57-61. Dent Implantol Update. 1994. PMID: 7919423 No abstract available.
-
Tridimensional reconstruction of knife-edge edentulous maxillae by sinus elevation, onlay grafts, and sagittal osteotomy of the anterior maxilla: preliminary surgical and prosthetic results.Int J Oral Maxillofac Implants. 1998 May-Jun;13(3):394-9. Int J Oral Maxillofac Implants. 1998. PMID: 9638010
-
Sinus lift and endosseous implants--preliminary surgical and prosthetic results.Eur J Prosthodont Restor Dent. 1994 Sep;3(1):15-21. Eur J Prosthodont Restor Dent. 1994. PMID: 8603146
-
Fixed rehabilitation of the edentulous maxilla: possibilities and clinical outcome.J Oral Maxillofac Surg. 2009 Nov;67(11 Suppl):60-73. doi: 10.1016/j.joms.2009.07.007. J Oral Maxillofac Surg. 2009. PMID: 19835751 Review.
-
Implant reconstruction of the bone-grafted maxilla: review of the literature and presentation of 8 cases.J Oral Maxillofac Surg. 2006 Apr;64(4):674-82. doi: 10.1016/j.joms.2005.12.026. J Oral Maxillofac Surg. 2006. PMID: 16546648 Review.
Cited by
-
Membrane perforation rate in lateral maxillary sinus floor augmentation using conventional rotating instruments and piezoelectric device-a meta-analysis.Int J Implant Dent. 2018 Jan 29;4(1):3. doi: 10.1186/s40729-017-0114-2. Int J Implant Dent. 2018. PMID: 29376211 Free PMC article. Review.
-
Three-Dimensional Evaluation of Implant Positioning in the Maxillary Sinus Septum: A Retrospective Study.Med Sci Monit. 2015 Sep 8;21:2666-71. doi: 10.12659/MSM.894403. Med Sci Monit. 2015. PMID: 26363865 Free PMC article.
-
Three-Dimensional Evaluation of Maxillary Sinus Septa for Implant Placement.Med Sci Monit. 2017 Mar 21;23:1394-1400. doi: 10.12659/msm.900327. Med Sci Monit. 2017. PMID: 28323814 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Medical