Quality assurance in the CHART clinical trial
- PMID: 8532912
- DOI: 10.1016/0167-8140(95)01598-b
Quality assurance in the CHART clinical trial
Abstract
As part of the clinical trial of CHART (continuous hyperfractionated accelerated radiotherapy) a quality assurance programme was included. The technical part of this--which is reported in this paper--is a series of tests designed to check all aspects of treatment planning and delivery. The results of visits to the 13 participating centres--and repeat visits to some of these centres--are discussed. The main areas tested were as follows. The linear accelerator: mechanical, and optical, scales and indicators; radiation field size; flatness and symmetry. DOSIMETRY: output; wedge factor; beam energy; phantom measurements against a plan calculated by the centre. SIMULATOR: mechanical, optical scales and indicators. The results show these centres work within the tolerances chosen for most parameters. Flatness, wedge factor and energy were areas of weakness in some centres. This must be partly the cause of the spread of phantom measurements which, after removal of variations in output, still range from -7 to +6% between calculated and measured values.
Similar articles
-
Credentialing of radiotherapy centres for a clinical trial of adaptive radiotherapy for bladder cancer (TROG 10.01).Radiother Oncol. 2012 Jun;103(3):293-8. doi: 10.1016/j.radonc.2012.03.003. Epub 2012 Apr 6. Radiother Oncol. 2012. PMID: 22483676
-
A multi-institutional evaluation of machine performance check system on treatment beam output and symmetry using statistical process control.J Appl Clin Med Phys. 2019 Mar;20(3):71-80. doi: 10.1002/acm2.12547. Epub 2019 Feb 20. J Appl Clin Med Phys. 2019. PMID: 30786139 Free PMC article.
-
Evaluation of the veridose QC phantom.Med Dosim. 2003 Spring;28(1):49-54. doi: 10.1016/S0958-3947(02)00249-2. Med Dosim. 2003. PMID: 12747620
-
Field flatness and symmetry of photon beams: review of the current recommendations.Technol Health Care. 2003;11(4):283-8. Technol Health Care. 2003. PMID: 14600339 Review.
-
Does quality of radiation therapy predict outcomes of multicenter cooperative group trials? A literature review.Int J Radiat Oncol Biol Phys. 2013 Oct 1;87(2):246-60. doi: 10.1016/j.ijrobp.2013.03.036. Epub 2013 May 15. Int J Radiat Oncol Biol Phys. 2013. PMID: 23683829 Free PMC article. Review.
Cited by
-
Quality assurance analysis of participating centres' protocol compliance to a UK multicentre hypofractionated breast (FAST) trial.Br J Radiol. 2012 Sep;85(1017):e647-53. doi: 10.1259/bjr/32249628. Epub 2012 Jan 31. Br J Radiol. 2012. PMID: 22294704 Free PMC article. Clinical Trial.
-
Association between radiotherapy protocol variations and outcome in the CONVERT trial.Clin Transl Radiat Oncol. 2022 Dec 13;39:100560. doi: 10.1016/j.ctro.2022.100560. eCollection 2023 Mar. Clin Transl Radiat Oncol. 2022. PMID: 36578530 Free PMC article.
-
One versus three weeks hypofractionated whole breast radiotherapy for early breast cancer treatment: the FAST-Forward phase III RCT.Health Technol Assess. 2023 Nov;27(25):1-176. doi: 10.3310/WWBF1044. Health Technol Assess. 2023. PMID: 37991196 Free PMC article. Clinical Trial.
-
Radiotherapy dosimetry audit: three decades of improving standards and accuracy in UK clinical practice and trials.Br J Radiol. 2015;88(1055):20150251. doi: 10.1259/bjr.20150251. Epub 2015 Sep 2. Br J Radiol. 2015. PMID: 26329469 Free PMC article.
-
Inter-departmental dosimetry audits - development of methods and lessons learned.J Med Phys. 2015 Oct-Dec;40(4):183-9. doi: 10.4103/0971-6203.170791. J Med Phys. 2015. PMID: 26865753 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials