Effects of storage time on quantitative and qualitative platelet function after transfusion
- PMID: 8533908
- DOI: 10.1097/00000542-199512000-00006
Effects of storage time on quantitative and qualitative platelet function after transfusion
Abstract
Background: Platelet transfusions are being used increasingly in patients with thrombocytopenia to improve hemostatic function before surgery and invasive procedures. However, there are limited data on the immediate quantitative and qualitative platelet response after transfusion. Some authors have suggested that transfused platelets require time in vivo to regain maximal function, which is dependent on the duration of platelet storage. Therefore, the timing of surgery and invasive procedures with optimal platelet function may not be occurring.
Methods: Twenty-five patients with thrombocytopenia from ablation chemotherapy and total body irradiation (before bone marrow transplantation), were randomized to receive either 1-day (fresh) or 4-day stored platelets. No patient had infection, organ system dysfunction, or previous platelet transfusion. Single-donor platelets were transfused (1 unit/10 kg body weight) over 60 min. Whole blood from an indwelling central venous catheter was obtained before, immediately after, and 1, 2, and 24 h after transfusion. Platelet number was measured on a Coulter counter and platelet reactivity was measured on a Coulter counter and platelet reactivity was measured using agonist-induced whole blood impedance aggregometry (ohms) and dense granule release (adenosine triphosphate [ATP]).
Results: Platelet number increased similarly (21,000 +/- 2,000/mm3 to 76,000 +/- 7,000/MM3 AND 20,000 +/- 1,000/MM3 TO 65,000 +/- 4,000/MM3) after transfusion in the 1- and 4-day stored platelets, respectively. These levels were maintained for 2 h after transfusion in both groups and then decreased similarly (26% and 27%) at 24 h. Agonist-induced platelet aggregation increased immediately after transfusion to 5 micrograms/ml collagen (0.7 +/- 0.4 to 11.4 +/- 1.0 ohms and 0.1 +/- 0.1 to 5.2 +/- 1.0 ohms), 10 micrograms/ml collagen, (1.5 +/- 0.7 to 18.0 +/- 1.9 ohms and 0.6 +/- 0.4 to 10.0 +/- 1.6 ohms) and ristocetin (0.7 +/- 0.4 to 10.1 +/- 1.7 and 0.1 +/- 0.7 to 6.2 +/- 1.0 ohms), in 1- and 4-day, stored platelets, respectively and persisted unchanged in both groups for 2 h. Fresh platelets were hyperaggregable compared to 4-day stored platelets for collagen-induced (5 micrograms/ml and 10 micrograms/ml) aggregation. Agonist-induced platelet dense granule release (ATP) increased immediately after transfusion to 5 micrograms/ml collagen (42 +/- 18 to 410 +/- 49 picomoles ATP and 20 +/- 7 to 186 +/- 22 picomoles ATP), 10 micrograms/ml collagen (60 +/- 22 to 449 +/- 53 picomoles ATP and 44 +/- 13 to 219 +/- 25 picomoles ATP in 1- and 4-day platelets, respectively. Ristocetin-induced ATP release increased immediately after transfusion of fresh platelets only (0 +/- 0 to 69 +/- 17) and remained unchanged for 2 h. Fresh platelets also demonstrated greater dense granule release to collagen (5 micrograms and 10 micrograms/ml) and ristocetin than 4-day stored platelets.
Conclusions: In patients with chemotherapy-induced thrombocytopenia, platelet transfusion causes an immediate increase in number and function, which is independent of storage time. This quantitative and qualitative increase persists unchanged for 2 h after transfusion, suggesting that there is no acute "warm-up-time" necessary for transfused platelets to regain maximal function. Fresh platelets demonstrate increased aggregation and dense granule release compared to 4-day stored platelets and may impart improved hemostatic function in vivo.
Similar articles
-
Evaluation of platelet function using the in vitro bleeding time and corrected count increment of transfused platelets. Comparison between platelet concentrates derived from pooled buffy coates and apheresis.Vox Sang. 1996;70(2):69-75. doi: 10.1111/j.1423-0410.1996.tb01296.x. Vox Sang. 1996. PMID: 8801766
-
Post-transfusion recovery of function of 5-day stored platelet concentrates.Br J Haematol. 1992 Apr;80(4):539-44. doi: 10.1111/j.1365-2141.1992.tb04570.x. Br J Haematol. 1992. PMID: 1581239
-
Permanent lesions of stored platelets correlate to pH and cell count while reversible lesions do not.Proc Soc Exp Biol Med. 1998 Feb;217(2):219-27. doi: 10.3181/00379727-217-44226. Proc Soc Exp Biol Med. 1998. PMID: 9452147
-
Cold stored platelets in the management of bleeding: is it about bioenergetics?Platelets. 2023 Dec;34(1):2188969. doi: 10.1080/09537104.2023.2188969. Platelets. 2023. PMID: 36922733 Review.
-
Cold-Stored Platelets: Review of Studies in Humans.Transfus Med Rev. 2020 Oct;34(4):221-226. doi: 10.1016/j.tmrv.2020.08.003. Epub 2020 Sep 16. Transfus Med Rev. 2020. PMID: 33039263 Review.
Cited by
-
Extended storage of autologous apheresis platelets in plasma.Vox Sang. 2013 May;104(4):324-30. doi: 10.1111/vox.12010. Epub 2013 Feb 6. Vox Sang. 2013. PMID: 23384253 Free PMC article.
-
Lessons Learned From the Battlefield and Applicability to Veterinary Medicine - Part 2: Transfusion Advances.Front Vet Sci. 2021 May 7;8:571370. doi: 10.3389/fvets.2021.571370. eCollection 2021. Front Vet Sci. 2021. PMID: 34026881 Free PMC article. Review.
-
The Non-Hemostatic Aspects of Transfused Platelets.Front Med (Lausanne). 2018 Feb 27;5:42. doi: 10.3389/fmed.2018.00042. eCollection 2018. Front Med (Lausanne). 2018. PMID: 29536007 Free PMC article. Review.
-
Cold storage of platelets in additive solution: the impact of residual plasma in apheresis platelet concentrates.Haematologica. 2019 Jan;104(1):207-214. doi: 10.3324/haematol.2018.195057. Epub 2018 Aug 16. Haematologica. 2019. PMID: 30115655 Free PMC article.
-
Platelets stored at 4°C contribute to superior clot properties compared to current standard-of-care through fibrin-crosslinking.Br J Haematol. 2017 Jul;178(1):119-129. doi: 10.1111/bjh.14751. Epub 2017 Jun 4. Br J Haematol. 2017. PMID: 28580719 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources