Review
. 1995 Fall;7(4):267-85.

MR angiography of the coronary arteries

Affiliations
  • PMID: 8534497
Review

MR angiography of the coronary arteries

A J Duerinckx. Top Magn Reson Imaging. 1995 Fall.

Abstract

Magnetic resonance angiography (MRA) of the coronary arteries has recently become possible due to the development of a new group of ultrafast imaging sequences. Coronary arteries are small, tortuous vessels subjected to significant physiological motions (respiration and cardiac contractions). Most coronary MRA pulse sequences rely on a combination of segmental acquisition of data (in k-space) to minimize cardiac motion artifacts and patient breath-holding to minimize respiratory motion artifacts. MR is noninvasive, does not require any contrast agents or ionizing radiation, and thus offers the potential of becoming a very important cardiac screening tool. Coronary MRA can routinely depict the proximal and middle portion of most coronary arteries and some coronary artery branches. However, its clinical utility for detecting lesions has not yet been proven. As coronary MRA techniques improve they may become an integral part of the evaluation of patients with ischemic heart disease. Existing coronary MRA techniques can already play a significant clinical role in the evaluation of coronary artery anomalies, in the follow-up of proximal lesions after angioplasty, and in the noninvasive determination of patency of bypass grafts and coronary stents.

PubMed Disclaimer

Similar articles

Cited by

  • Two-dimensional coronary MRA: limitations and artifacts.
    Duerinckx AJ, Atkinson DP, Mintorovitch J, Simonetti OP, Vrman MK. Duerinckx AJ, et al. Eur Radiol. 1996;6(3):312-25. doi: 10.1007/BF00180601. Eur Radiol. 1996. PMID: 8798000
  • MRI of coronary arteries.
    Duerinckx AJ. Duerinckx AJ. Int J Card Imaging. 1997 Jun;13(3):191-7. doi: 10.1023/a:1005791317440. Int J Card Imaging. 1997. PMID: 9220281 Review.
  • Coronary MR angiography.
    Duerinckx AJ. Duerinckx AJ. Int J Cardiovasc Imaging. 2001 Dec;17(6):467-9; quiz 469. doi: 10.1023/a:1020133115225. Int J Cardiovasc Imaging. 2001. PMID: 12365547 Review. No abstract available.