Comparison of two reflectance photometers in the assessment of neonatal hypoglycaemia
- PMID: 8535875
- PMCID: PMC2528469
- DOI: 10.1136/fn.73.3.f170
Comparison of two reflectance photometers in the assessment of neonatal hypoglycaemia
Abstract
To assess the accuracy and reliability of reflectance photometers in estimating blood glucose concentrations, two were assessed: the Ames Glucometer 3 (Bayer Diagnostics) with Glucofilm Test strips; and the Reflolux S (Boehringer Mannheim) with BM Test Glycemia 20-800 strips. These were compared with laboratory blood glucose estimations in 100 assays (50 comparisons for each machine, measuring the difference (d) between the glucose reading and the mean of the reflectance photometer and the laboratory value). The Ames Glucometer 3 (mean d = + 0.7 mmol/l, (SD 1.1) mmol/l) was less accurate than the Boehringer Reflolux S (mean d = 0.2 mmol/l, (SD (0.7) mmol/l). The range of error of both machines is wide (Ames 2 SD range + 2.9 mmol/l to -1.5 mmol/l true readings; Boehringer + 1.8 mmol/l to -1.2 mmol/l of true readings). Because of this, any reflectance photometer readings that are even slightly low should be checked with laboratory estimations. The clinical value of such machines is limited in infants with low blood glucose concentrations.
Similar articles
-
Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice.Arch Dis Child Fetal Neonatal Ed. 2004 Jul;89(4):F356-9. doi: 10.1136/adc.2003.033548. Arch Dis Child Fetal Neonatal Ed. 2004. PMID: 15210675 Free PMC article.
-
Blood glucose monitoring by children at home: a comparison of methods.Aust Paediatr J. 1986 Nov;22(4):309-12. doi: 10.1111/j.1440-1754.1986.tb02155.x. Aust Paediatr J. 1986. PMID: 3566680
-
An evaluation and comparison of Reflolux II and Glucometer II, two new portable reflectance meters for capillary blood glucose determination.Diabetes Res Clin Pract. 1988 Feb 19;4(3):177-81. doi: 10.1016/s0168-8227(88)80015-9. Diabetes Res Clin Pract. 1988. PMID: 3359917
-
Ward and laboratory assessment of two second-generation blood-glucose monitoring systems.Med J Aust. 1988 Oct 17;149(8):420-4. doi: 10.5694/j.1326-5377.1988.tb120702.x. Med J Aust. 1988. PMID: 3173204
-
[Assessment of neonatal hypoglycemia with 2 test strip methods].Monatsschr Kinderheilkd. 1988 Oct;136(10):694-7. Monatsschr Kinderheilkd. 1988. PMID: 3237224 German.
Cited by
-
Comparison of two cotside methods for the detection of hypoglycaemia among neonates in Nepal.Arch Dis Child Fetal Neonatal Ed. 1996 Sep;75(2):F122-5. doi: 10.1136/fn.75.2.f122. Arch Dis Child Fetal Neonatal Ed. 1996. PMID: 8949696 Free PMC article. Clinical Trial.
-
Evaluation of "point of care" devices in the measurement of low blood glucose in neonatal practice.Arch Dis Child Fetal Neonatal Ed. 2004 Jul;89(4):F356-9. doi: 10.1136/adc.2003.033548. Arch Dis Child Fetal Neonatal Ed. 2004. PMID: 15210675 Free PMC article.
-
Hypoglycemia in small for gestational age babies.Indian J Pediatr. 2000 Jun;67(6):423-7. doi: 10.1007/BF02859459. Indian J Pediatr. 2000. PMID: 10932962
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical