Extracellular glutamate: on-line monitoring using microdialysis coupled to enzyme-amperometric analysis
- PMID: 8544467
- DOI: 10.1016/0165-0270(94)00214-2
Extracellular glutamate: on-line monitoring using microdialysis coupled to enzyme-amperometric analysis
Abstract
An enzyme-amperometric detector cell is described for flow analysis of glutamate in dialysate emerging from an implanted microdialysis probe. Its small size allows it to be placed within a few centimetres of the animal preparation, reducing the delay for data acquisition to around 2 min. The selectivity is provided by glutamate oxidase, immobilised with glutaraldehyde on surfaces adjacent to the 3-electrode system. A film of 1,2-diaminobenzene, electropolymerized on the platinum working electrode, eliminates interference from ascorbic acid and other endogenous electroactive compounds. The high sensitivity (< 0.5 mumol/l) and fast response time of the cell (90% of maximum response in 30 s) make it particularly suitable for investigating conditions that produce rapid changes in brain extracellular glutamate. This is illustrated by monitoring changes in extracellular glutamate subsequent to cardiac arrest, and K(+)-induced local depolarization.
Similar articles
-
Micro-flow in vivo analysis of L-glutamate with an on-line enzyme amplifier based on substrate recycling.Anal Sci. 2001 Jun;17(6):703-8. doi: 10.2116/analsci.17.703. Anal Sci. 2001. PMID: 11707939
-
Simultaneous determination of L-glutamate, acetylcholine and dopamine in rat brain by a flow-injection biosensor system with microdialysis sampling.Anal Sci. 2008;24(11):1469-73. doi: 10.2116/analsci.24.1469. Anal Sci. 2008. PMID: 18997377
-
An improved method for the detection of changes in brain extracellular glutamate levels.J Neurosci Methods. 1998 Jun 1;81(1-2):199-205. doi: 10.1016/s0165-0270(98)00041-7. J Neurosci Methods. 1998. PMID: 9696326
-
Brain microdialysis of GABA and glutamate: what does it signify?Synapse. 1997 Nov;27(3):242-61. doi: 10.1002/(SICI)1098-2396(199711)27:3<242::AID-SYN9>3.0.CO;2-D. Synapse. 1997. PMID: 9329159 Review.
-
Clinical microdialysis: the role of on-line measurement and quantitative microdialysis.Acta Neurochir Suppl. 1996;67:13-20. doi: 10.1007/978-3-7091-6894-3_3. Acta Neurochir Suppl. 1996. PMID: 8870794 Review.
Cited by
-
Microdialysis techniques and microdialysis-based patient-near diagnostics.Anal Bioanal Chem. 2022 Apr;414(10):3165-3175. doi: 10.1007/s00216-021-03830-6. Epub 2022 Jan 14. Anal Bioanal Chem. 2022. PMID: 35028692 Review.
-
Flow biosensing and sampling in indirect electrochemical detection.Biomicrofluidics. 2012 Jun;6(2):24114-2411413. doi: 10.1063/1.4705368. Epub 2012 Apr 20. Biomicrofluidics. 2012. PMID: 22655022 Free PMC article.
-
Pharmacokinetic and metabolism studies using microdialysis sampling.J Pharm Sci. 1999 Jan;88(1):14-27. doi: 10.1021/js9801485. J Pharm Sci. 1999. PMID: 9874697 Free PMC article. Review. No abstract available.
-
Deuterated Glutamate-Mediated Neuronal Activity on Micro-Electrode Arrays.Micromachines (Basel). 2020 Aug 31;11(9):830. doi: 10.3390/mi11090830. Micromachines (Basel). 2020. PMID: 32878218 Free PMC article.
-
Effects of 4-aminopyridine on extracellular concentrations of glutamate in striatum of the freely moving rat.Neurochem Res. 1997 Dec;22(12):1491-7. doi: 10.1023/a:1021958613125. Neurochem Res. 1997. PMID: 9357015
Publication types