Acoustic properties of selected bovine tissues in the frequency range 20-200 MHz
- PMID: 8550930
- DOI: 10.1121/1.413827
Acoustic properties of selected bovine tissues in the frequency range 20-200 MHz
Abstract
The acoustic properties of freshly excised bovine liver, heart muscle, and fat are characterized in the frequency range 20-200 MHz by the bioultrasonic spectroscopy system using an ultrasonic transmission comparison method. Significant differences are obtained in the attenuation coefficient, velocity, impedance, and density among these tissues. Measurements of aqueous solutions of bovine hemoglobin are also reported in order to compare the contribution of the protein content to the acoustic properties. The differences among the acoustic properties of liver and heart muscle can be described in terms of their protein contents and other molecular constituents.
Similar articles
-
Acoustic properties of egg yolk and albumen in the frequency range 20-400 MHz.J Acoust Soc Am. 1997 Dec;102(6):3774-8. doi: 10.1121/1.420404. J Acoust Soc Am. 1997. PMID: 9407669
-
Performance of ultrasonic speckle tracking in various tissues.J Acoust Soc Am. 1995 Sep;98(3):1273-8. doi: 10.1121/1.414453. J Acoust Soc Am. 1995. PMID: 7560501
-
Influence of histochemical preparation on acoustic parameters of liver tissue: a 5-MHz study.Ultrasound Med Biol. 1991;17(9):879-91. doi: 10.1016/0301-5629(91)90083-9. Ultrasound Med Biol. 1991. PMID: 1725228
-
Measurements of acoustic properties of aqueous dextran solutions in the VHF/UHF range.Ultrasonics. 2000 Sep;38(9):915-9. doi: 10.1016/s0041-624x(00)00015-9. Ultrasonics. 2000. PMID: 11012014
-
Review of the Low-Temperature Acoustic Properties of Water, Aqueous Solutions, Lipids, and Soft Biological Tissues.IEEE Trans Ultrason Ferroelectr Freq Control. 2024 May;71(5):607-620. doi: 10.1109/TUFFC.2024.3381451. Epub 2024 May 10. IEEE Trans Ultrason Ferroelectr Freq Control. 2024. PMID: 38530713 Review.
Cited by
-
Low-cost, high-speed back-end processing system for high-frequency ultrasound B-mode imaging.IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Jul;56(7):1490-7. doi: 10.1109/TUFFC.2009.1205. IEEE Trans Ultrason Ferroelectr Freq Control. 2009. PMID: 19574160 Free PMC article.
-
Measurements of the anisotropy of ultrasonic velocity in freshly excised and formalin-fixed myocardial tissue.J Acoust Soc Am. 2005 Jul;118(1):505-13. doi: 10.1121/1.1925947. J Acoust Soc Am. 2005. PMID: 16119369 Free PMC article.
-
Ultrasonic characterization of porcine liver tissue at frequency between 25 to 55 MHz.World J Gastroenterol. 2006 Apr 14;12(14):2276-9. doi: 10.3748/wjg.v12.i14.2276. World J Gastroenterol. 2006. PMID: 16610036 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources