Immunoglobulin G can cross-react with glucagon antisera and cause a spuriously high plasma immunoreactive glucagon level
- PMID: 8556050
- DOI: 10.1507/endocrj.42.455
Immunoglobulin G can cross-react with glucagon antisera and cause a spuriously high plasma immunoreactive glucagon level
Abstract
We had a patient with asymptomatic hyper-immunoreactive glucagonemia and with no evidence of pancreatic tumor detected by radiological examinations. The glucagon level was not decreased by the administration of glucose or somatosatin analogue (SMS 201-995). Gel filtration studies revealed that most glucagon immunoreactivity was eluted at the position of 150,000 daltons [big plasma glucagon (BPG)]. Binding studies with 125I-glucagon showed that glucagon autoantibody was negative. Acid treatment of plasma and reduction of immunoglobulin G (IgG) did not result in a shift of BPG to normal glucagon (3485 daltons). Glucagon immunoreactivity determined with anti-glucagon antiserum OAL 123 (C-terminal specific antiserum used in the present radioimmunoassay kit) did not dilute out in parallel to normal glucagon (3485 daltons), and the plasma glucagon level was normal with Unger's 30K (anther C-terminal specific antiserum) and OAL 196 (N-terminal specific antiserum). The patient's IgG dose-dependently reduced the binding of 125I-glucagon to anti-glucagon antiserum OAL-123. Glucagon degrading activity (GDA) was negative in the patient's plasma. These results suggest that the patient's IgG cross-reacted with the present anti-glucagon antiserum OAL 123, and caused a spuriously high plasma immunoreactive glucagon level.
Similar articles
-
Discrepancy of fasting plasma glucagon levels measured by different glucagon antisera.Diabetes Res. 1988 Apr;7(4):179-83. Diabetes Res. 1988. PMID: 3402167
-
The first case of insulin-dependent diabetes mellitus with prominent spurious hyperglucagonemia due to interference of immunoglobulin G in glucagon radioimmunoassay (OAL-123) system.Horm Res. 1996;45(6):295-9. doi: 10.1159/000184809. Horm Res. 1996. PMID: 8793525
-
Glucagon radioimmunoassay with use of antiserum to glucagon C-terminal fragment.Clin Chem. 1981 Oct;27(10):1690-7. Clin Chem. 1981. PMID: 6169468
-
Persistent pancreatic glucagon but not insulin response to arginine in pancreatectomized dogs.Endocrinology. 1975 Mar;96(3):678-93. doi: 10.1210/endo-96-3-678. Endocrinology. 1975. PMID: 1116479
-
Production of a specific antiserum by synthetic C-terminal fragment of glucagon.Horm Metab Res. 1979 Aug;11(8):463-8. doi: 10.1055/s-0028-1092762. Horm Metab Res. 1979. PMID: 574120