Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats
- PMID: 8558488
- DOI: 10.1111/j.1939-1676.1995.tb03301.x
Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats
Abstract
Blood pressure (BP) measurements obtained using 3 indirect BP measuring instruments, a Doppler ultrasonic flowmeter, an oscillometric device, and a photoplethysmograph, were compared with direct arterial pressure measurements in 11 anesthetized cats. The standard deviation of the differences (SDD) between direct and indirect pressure measurements were not significantly different from each other (P < .01), and ranged from 10.82 to 24.32 mm Hg. The high SDD values indicate that indirect BP estimates obtained with all these devices must be interpreted cautiously in individual patients. The mean errors (calculated as the sum of the differences between direct and indirect pressure measurements divided by the number of observations) of the 3 indirect devices were significantly different for systolic (SAP), diastolic (DAP), and mean (MAP) arterial pressures (P < .05). The Doppler and photoplethysmographic devices had the highest overall accuracy, as indicated by mean error values of less than 10 mm Hg. Correlation coefficients varied from .88 to .96 for the Doppler flowmeter, and from .85 to .94 for the photoplethysmograph; for both devices, the regression line slopes were close to unity. The Doppler flowmeter detected a pulse under all experimental conditions. The photoplethysmograph was also efficient in obtaining BP measurements, obtaining over 90% of SAP, DAP, and MAP readings attempted. The oscillometric device was the least accurate, with mean error values varying from 10 to 22 mm Hg. Correlation coefficients were high (.90 to .94) for this device, but the slopes of the regression lines were 0.7 to 0.8, indicating a trend for increased error at higher BP. The oscillometric device tended to underestimate BP by increasing amounts as the BP increased. The oscillometric device was the least efficient device for obtaining BP measurements (P < .01).
Similar articles
-
Evaluation of noninvasive oscillometric blood pressure monitoring in anesthetized boid snakes.J Am Vet Med Assoc. 2009 Mar 1;234(5):625-30. doi: 10.2460/javma.234.5.625. J Am Vet Med Assoc. 2009. PMID: 19250041
-
Comparison of two species-specific oscillometric blood pressure monitors with direct blood pressure measurement in anesthetized cats.J Vet Emerg Crit Care (San Antonio). 2017 Jul;27(4):409-418. doi: 10.1111/vec.12623. Epub 2017 Jun 27. J Vet Emerg Crit Care (San Antonio). 2017. PMID: 28654723
-
Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs.J Vet Emerg Crit Care (San Antonio). 2010 Apr 1;20(2):207-15. doi: 10.1111/j.1476-4431.2010.00520.x. J Vet Emerg Crit Care (San Antonio). 2010. PMID: 20487248
-
Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats.J Am Vet Med Assoc. 2002 Sep 1;221(5):646-50. doi: 10.2460/javma.2002.221.646. J Am Vet Med Assoc. 2002. PMID: 12216901
-
[Non-invasive blood pressure measurement in dogs and cats].Tijdschr Diergeneeskd. 2005 Apr 1;130(7):198-201. Tijdschr Diergeneeskd. 2005. PMID: 15822444 Review. Dutch.
Cited by
-
Experimental study on the effects of isoflurane with and without remifentanil or dexmedetomidine on heart rate variability before and after nociceptive stimulation at different MAC multiples in cats.BMC Vet Res. 2019 Jul 24;15(1):258. doi: 10.1186/s12917-019-2004-8. BMC Vet Res. 2019. PMID: 31340857 Free PMC article.
-
Review of non-invasive blood pressure measurement in animals: Part 2 - Evaluation of the performance of non-invasive devices.Can Vet J. 2020 May;61(5):481-498. Can Vet J. 2020. PMID: 32355347 Free PMC article. Review.
-
Constant-Rate Infusion of Dexmedetomidine to Manage Thiopental Anesthesia during Intracranial Surgery in Cynomolgus Macaques (Macaca fascicularis).J Am Assoc Lab Anim Sci. 2016 Nov;55(6):801-804. J Am Assoc Lab Anim Sci. 2016. PMID: 27931320 Free PMC article.
-
A comparison of CAT Doppler and oscillometric Memoprint machines for non-invasive blood pressure measurement in conscious cats.J Feline Med Surg. 2005 Jun;7(3):147-52. doi: 10.1016/j.jfms.2004.08.003. J Feline Med Surg. 2005. PMID: 15922221 Free PMC article.
-
Non-invasive evaluation of the haemodynamic effects of high-dose medetomidine in healthy cats for semen collection.J Feline Med Surg. 2016 Apr;18(4):337-43. doi: 10.1177/1098612X15583345. Epub 2015 May 5. J Feline Med Surg. 2016. PMID: 25944580 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous