. 1996 Feb;82(2):251-3.
doi: 10.1097/00000539-199602000-00006.

Displacement of the endotracheal tube caused by change of head position in pediatric anesthesia: evaluation by fiberoptic bronchoscopy

Affiliations

Displacement of the endotracheal tube caused by change of head position in pediatric anesthesia: evaluation by fiberoptic bronchoscopy

K Sugiyama et al. Anesth Analg. 1996 Feb.

Abstract

Displacement of the endotracheal tube (ETT) caused by flexion and extension of the neck and the placement of a tongue depressor was investigated in 10 small children between the ages of 16 and 19 mo by means of a fiberoptic bronchoscope. The ETT tip moved a mean distance of 0.9 cm toward the carina with flexion and 1.7 cm toward the vocal cords with extension of the neck. After the placement of a tongue depressor, the ETT tip, which had once moved toward the vocal cords with neck extension, was displaced a mean distance of 1.2 cm toward the carina. Our results demonstrate that endobronchial intubation and accidental extubation could occur after significant changes of the head position and careless placement of a tongue depressor in small children.

PubMed Disclaimer