Clinical Trial
. 1996 Feb 1;93(3):463-73.
doi: 10.1161/01.cir.93.3.463.

Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography

Affiliations
Clinical Trial

Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography

E P Ficaro et al. Circulation. .

Abstract

Background: The purpose of the present study was to assess the diagnostic performance of attenuation-corrected (AC) stress 99mTc-sestamibi cardiac single-photon emission computed tomography (SPECT) for the identification of coronary heart disease (CHD).

Methods and results: With a triple-detector SPECT system with a 241Am transmission line source, simultaneous transmission/emission tomography (TCT/ECT) was performed on 60 patients with angiographic coronary disease and 59 patients with < or = 5% likelihood of CHD. Iteratively reconstructed AC stress 99mTc-sestamibi perfusion images were compared with uncorrected (NC) filtered-backprojection images. Normal database polar maps were constructed from AC and NC images for quantitative analyses. From the low-likelihood patients, the visual and quantitative normalcy rates increased from 0.88 and 0.76 for NC to 0.98 and 0.95 for AC (P < .05). For the detection of CHD, the receiver operating characteristic curves for the AC images demonstrated improved discrimination capacity (P < .05), and sensitivity/specificity values increased from 0.78/0.46 (NC) to 0.84/0.82 (AC) with visual analysis and from 0.84/0.46 (NC) to 0.88/0.82 (AC) with quantitative analysis. For localization of stenosed vessels, visual and quantitative sensitivity values were 0.51 and 0.63 for NC and 0.64 and 0.78 for AC images (P < .05), respectively.

Conclusions: TCT/ECT myocardial perfusion imaging significantly improves the diagnostic accuracy of cardiac SPECT for the detection and localization of CHD. Clinical use of TCT/ECT imaging deserves serious consideration.